Immediate implant placement after removal of a failed implant: a clinical and histological case report

Ugo Covani,Simone Marconcini,Roberto Crespi,Antonio Barone
DOI: https://doi.org/10.1563/1548-1336-35.4.189
Abstract:The purpose of this study was to evaluate the clinical success of an implant placed immediately after the explantation of a fractured blade implant. A healthy 58-year-old male nonsmoker presented with a fractured blade implant that had been subjected to biomechanical overload. A new blade implant was placed immediately after the removal of the fractured one. The new implant was placed with a composite graft of collagen gel and corticocancellous porcine bone and covered with a bioabsorbable membrane. Radiographic evaluation at 6 months postoperation showed complete bone healing. No residual bone defect was observed or probed during the uncovering phase; moreover, no mobility, pain, suppuration, or presence of peri-implant radiolucency were observed at the second-stage surgery.