Monitoring method for axis alignment of single-mode optical fiber and splice-loss estimation.

T. Haibara,M. Mals-Umoto,T. Tanifuji,M. Tokuda
DOI: https://doi.org/10.1364/OL.8.000235
IF: 3.6
1983-04-01
Optics Letters
Abstract:A new method for core-axis alignment and precise splice-loss estimation for single-mode optical fibers is presented. By using a differential interference contrast microscope, we can achieve core-axis alignment with an offset below 0.3 microm, which results in a butt-joint loss increase of 0.04 dB compared with that obtained by alignment using a conventional optical monitoring method. Furthermore, splice-loss estimation with a precision of 0.05 dB is attained for a low-loss region without using an index-matching liquid.
What problem does this paper attempt to address?