Real-time antiproton annihilation vertexing with sub-micron resolution
M. Berghold,D. Orsucci,F. Guatieri,S. Alfaro,M. Auzins,B. Bergmann,P. Burian,R. S. Brusa,A. Camper,R. Caravita,F. Castelli,G. Cerchiari,R. Ciuryło,A. Chehaimi,G. Consolati,M. Doser,K. Eliaszuk,R. Ferguson,M. Germann,A. Giszczak,L. T. Glöggler,Ł. Graczykowski,M. Grosbart,F. Guatieri,N. Gusakova,F. Gustafsson,S. Haider,S. Huck,C. Hugenschmidt,M. A. Janik,T. Januszek,G. Kasprowicz,K. Kempny,G. Khatri,Ł. Kłosowski,G. Kornakov,V. Krumins,L. Lappo,A. Linek,S. Mariazzi,P. Moskal,D. Nowicka,P. Pandey,D. Pęcak,L. Penasa,V. Petracek,M. Piwiński,S. Pospisil,L. Povolo,F. Prelz,S. A. Rangwala,T. Rauschendorfer,B. S. Rawat,B. Rienäcker,V. Rodin,O. M. Røhne,H. Sandaker,S. Sharma,P. Smolyanskiy,T. Sowiński,D. Tefelski,T. Vafeiadis,M. Volponi,C. P. Welsch,M. Zawada,J. Zielinski,N. Zurlo
2024-06-23
Abstract:The primary goal of the AEgIS experiment is to precisely measure the free fall of antihydrogen within Earth's gravitational field. To this end, a cold ~50K antihydrogen beam has to pass through two grids forming a moiré deflectometer before annihilating onto a position-sensitive detector, which shall determine the vertical position of the annihilation vertex relative to the grids with micrometric accuracy. Here we introduce a vertexing detector based on a modified mobile camera sensor and experimentally demonstrate that it can measure the position of antiproton annihilations with an accuracy of $0.62^{+0.40}_{-0.22}\mu m$, which represents a 35-fold improvement over the previous state-of-the-art for real-time antiproton vertexing. Importantly, these antiproton detection methods are directly applicable to antihydrogen. Moreover, the sensitivity to light of the sensor enables the in-situ calibration of the moiré deflectometer, significantly reducing systematic errors. This sensor emerges as a breakthrough technology for achieving the \aegis scientific goals and has been selected as the basis for the development of a large-area detector for conducting antihydrogen gravity measurements.
Instrumentation and Detectors