Multi-slice passband bSSFP fMRI at ultra-high field

Olivier Reynaud,Analina R. da Silva,Rolf Gruetter,Ileana O. Jelescu
DOI: https://doi.org/10.1016/j.jmr.2019.05.010
2018-12-11
Abstract:Balanced steady-state free precession (bSSFP) can be used as an alternative to gradient-echo (GE) EPI for BOLD functional MRI when image distortions and signal drop-outs are severe such as at ultra-high field. However, 3D-bSSFP acquisitions have distinct drawbacks on either human or animal MR systems. On clinical scanners, 3D imaging is suboptimal for localized fMRI applications, and also results in distortions, blurring, and increased sensitivity to motion or physiological noise. On pre-clinical systems, 3D acquisitions have low temporal resolution due to limited acceleration options, while single slice offers insufficient coverage. The aim of the present study was to implement a multi-slice bSSFP acquisition with Cartesian read-out to obtain non-distorted BOLD fMRI activation maps in the human and rat brain at ultra-high field. We show that the bSSFP signal characteristics are preserved in a new pseudo-steady-state. In the human brain at 7 Tesla, we demonstrate that both task- and resting-state fMRI can be performed with 2D-bSSFP, with a temporal SNR that matches that of 3D-bSSFP, resulting in - at least - equal performance. In the rat brain at 14 Tesla, we show that the multi-slice bSSFP protocol has similar sensitivity to gradient-echo EPI for task fMRI, while benefitting from much reduced distortions and drop-outs. The advantages of passband bSSFP at 14 Tesla in comparison with GE-EPI are expected to be even more marked for mouse fMRI.
Medical Physics,Biological Physics
What problem does this paper attempt to address?
This paper aims to solve the problems encountered in functional magnetic resonance imaging (fMRI) in an ultra - high magnetic field environment. Specifically, the paper attempts to solve the following two main problems: 1. **Image distortion and signal loss**: When fMRI is performed using the traditional gradient - echo (GE) echo - planar imaging (EPI) technique in an ultra - high magnetic field, there are problems of spatial distortion and signal loss due to B0 inhomogeneity. These problems make it difficult to align the images with anatomical reference images, and there is a severe signal loss in the susceptibility - mismatched areas at the air - tissue interface. 2. **Limitations of 3D - bSSFP acquisition**: Although the balanced steady - state free precession (bSSFP) sequence can provide a high signal - to - noise ratio (SNR) and reduce distortion and signal loss, 3D - bSSFP acquisition has some limitations on clinical scanners, such as sub - optimal performance in local fMRI applications, image distortion, blurring, and increased sensitivity to motion or physiological noise. In pre - clinical systems, 3D acquisition has a lower temporal resolution due to limited acceleration options, while single - layer acquisition has insufficient coverage. To solve the above problems, this study proposes a multi - layer bSSFP acquisition method with a Cartesian read - out mode to obtain distortion - free BOLD fMRI activation maps. This method was verified in the human brain (7 Tesla) and the rat brain (14 Tesla), and the results showed that: - In the human brain at 7 Tesla, 2D - bSSFP shows performance comparable to that of 3D - bSSFP in task - based and resting - state fMRI, and the temporal SNR matches or is better than that of 3D - bSSFP. - In the rat brain at 14 Tesla, the multi - layer bSSFP protocol has a sensitivity in task - based fMRI comparable to that of gradient - echo EPI, but with significantly reduced distortion and signal loss. In conclusion, this study solves the problems of fMRI image distortion and signal loss in an ultra - high magnetic field environment by implementing the multi - layer bSSFP acquisition method, while improving image quality and spatio - temporal resolution.