Measurement of the neutron lifetime using a magneto-gravitational trap

Nathan Callahan
2018-10-02
Abstract:Precision measurements of the free neutron lifetime $\tau_n$, when combined with measurements of the axial vector form factor, can be used to test unitarity of the CKM matrix. Non-unitarity is a signal for physics Beyond the Standard Model (BSM). Sensitivity to BSM physics requires measurements of $\tau_n$ to a precision of 0.1~s. However, the two dominant techniques to measure $\tau_n$ (colloquially beam and bottle measurements) disagree by nearly 10~s. UCN$\tau$ is a neutron lifetime experiment using a magneto-gravitational trap and an in-situ neutron detector. Neutrons in this trap are not susceptible to loss on material walls as in previous bottle measurements. Additionally, the in-situ detector allows spectral monitoring of the trapped Ultracold Neutrons. In this talk, I will present our most recent result - $\tau_n=877.7\pm0.7_\text{(stat.)}+0.4/-0.2_\text{(sys.)}$~s. I will also present Monte Carlo simulations of systematic effects in the experiment including heating and spectral cleaning.
Instrumentation and Detectors
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the inconsistency in the measurement of the free neutron lifetime (\(\tau_n\)). Specifically, there are significant differences in the results of measuring the free neutron lifetime using different methods. In particular, the results between "beam measurements" and "bottle measurements" differ by nearly 10 seconds. This difference is of great significance for testing the unitarity of the CKM matrix and exploring new physics beyond the Standard Model (BSM). Therefore, improving the precision of free neutron lifetime measurement to 0.1 seconds can provide key clues for the exploration of new physics. The UCN \(\tau\) experiment introduced in the paper adopts a new method - a magnetic - gravity trap combined with an in - situ neutron detector - to measure the free neutron lifetime. This method aims to reduce the systematic errors caused by neutron loss on the material wall in traditional bottle - method experiments, and monitor the energy - spectrum changes of ultracold neutrons through in - situ detectors, thereby providing more accurate measurement results. The authors report the latest experimental results, that is, the neutron lifetime is \(877.7 \pm 0.7 (\text{stat.}) +0.4 / -0.2 (\text{sys.})\) seconds, and discuss the evaluation of systematic effects in the experiment and Monte Carlo simulation studies. These works help to clarify the current differences in neutron lifetime measurement and lay the foundation for future high - precision measurements.