Temporal variations in scattering and dispersion measure in the Crab Pulsar and their effect on timing precision

J. W. McKee,A. G. Lyne,B. W. Stappers,C. G. Bassa,C. A. Jordan
DOI: https://doi.org/10.1093/mnras/sty1727
2018-06-27
Abstract:We have measured variations in scattering time scales in the Crab Pulsar over a 30-year period, using observations made at 610 MHz with the 42-ft telescope at Jodrell Bank Observatory. Over more recent years, where regular Lovell Telescope observations at frequencies around 1400 MHz were available, we have also determined the dispersion measure variations, after disentangling the scattering delay from the dispersive delay. We demonstrate a relationship between scattering and dispersion measure variations, with a correlation coefficient of $0.56\pm0.01$. The short time scales over which these quantities vary, the size of the variations, and the close correlation between scattering and dispersion measure all suggest that the effects are due to discrete structures within the Crab Nebula, with size scales of $\sim6$ AU (corresponding to an angular size of $\sim2$ mas at an assumed distance of 2200 pc). We mitigate the effects of scattering on the observed pulse shape by using the measured scattering information to modify the template used for generating the pulse arrival times, thus improving the precision to which the pulsar can be timed. We test this on timing data taken during periods of high scattering, and obtain a factor of two improvement in the root mean square of the timing residuals.
High Energy Astrophysical Phenomena
What problem does this paper attempt to address?
The problem that this paper attempts to solve is about the variation of the scattering time and dispersion measure (DM) of the Crab Pulsar over time and their influence on the precision of the pulse arrival time (Timing Precision). Specifically, through long - term (30 - year) observations of the pulse shape changes of the Crab Pulsar at 610 MHz and 1400 MHz frequencies, the researchers measured the changes in scattering time and DM and analyzed the relationship between these changes and the pulsar timing precision. ### Research Background The Crab Pulsar (PSR B0531 + 21 or PSR J0534 + 2200) is located at the center of the Crab Nebula and is the core of the supernova remnant in 1054. Due to the rapid rotation energy of the pulsar, the surrounding area is activated, forming a pulsar - wind nebula. There are density fluctuations, clouds, and irregular turbulent regions inside the nebula. These structures cause radio waves to scatter and disperse during propagation. This effect is more significant than that of typical pulsars because the electron number density in the Crab Nebula changes more and on a shorter time scale. ### Research Methods The researchers used the 42 - foot telescope and Lovell telescope at the Jodrell Bank Observatory to conduct almost daily observations for 30 years. The main observation frequency was 610 MHz, and each observation lasted about 10 hours. In addition, the observation data of the Lovell telescope at 1400 MHz were also used, with each observation lasting 12 minutes. Through these data, the researchers measured the changes in the scattering time and DM of the pulsar. ### Main Findings 1. **Changes in Scattering Time and DM**: - 64% of the scattering time scale is between 0.05 ms and 0.15 ms, and the median value is about 0.13 ms. - There is a significant correlation between the scattering time scale and DM, with a correlation coefficient of 0.56 ± 0.01. - The change in the scattering time scale is closely related to the change in DM, especially during high - scattering periods. 2. **Structure Function Analysis**: - Through the structure function analysis of the DM time series, three different regions were found: the noise region, the structure region, and the saturation region. - The power - law index in the structure region is 0.69 ± 0.04, which is less than 5/3 predicted by Kolmogorov turbulence. - The characteristic time scale is about 70 days, corresponding to the length scale of the high - density region in the nebula of about 6 AU (about 2×10^-5 pc). 3. **Improvement in Timing Precision**: - By using the measured scattering information to correct the template, the timing precision of the pulsar can be significantly improved. - During high - scattering periods, the standard deviation (RMS) of the timing residuals can be reduced by more than a factor of two. ### Conclusion The research results show that the discrete structures in the Crab Nebula may be the cause of the large increases in DM and scattering. By correcting the effects of scattering and DM, the timing precision of the pulsar can be significantly improved, thereby better studying the rotation evolution and glitches of the pulsar. These findings are helpful for understanding the scattering effect in pulsar observations and the nature of the Crab Nebula environment.