Abstract:We demonstrate the influence of hard axis assist on an in-plane polarized nanomagnet layer to greatly enhance the sensitivity of a magnetic nano particle (MNP) based MTJ biosensor. The hard axis assist has been provided to the sensing layer in the forms of spin Hall Effect (SHE) induced spin injected torque and stress based effective magnetic field induced torque separately. Present work mainly focuses on the efficient and qualitative detection of a single magnetic bead with the aim of detecting a single bimolecular recognition event at an extremely low analyte concentration. Interfacial spin current arising from spin orbit metal is expected to impose a torque on the free layer along sensitive direction improving the signal strength by a factor of ~ 6.5 for a 100 nm bead at a height of 500 nm above the sensor surface. Furthermore, the potentiality of a multiferroic composite consisting of a piezoelectric layer coupled with magnetostrictive CoFeB based MTJ has been investigated in the Biosensing applications. An external stress voltage of 500 mV has been observed to be sufficient to enhance the sensitivity (~ 6 times). The use of nanoscaled spin devices and the absence of external magnetic field operated magnetization rotation facilitates in achieving highly compact and extremely low power designs. This establishes the possibility of utilizing the present schemes for advanced, highly sensitive, miniaturized and low power bioassaying system-on-chip applications. Numerical results were compared with some earlier reported experimental results to validate our proposed model.
Mesoscale and Nanoscale Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to improve the sensitivity of magnetic tunnel junction (MTJ) - based biosensors using magnetic nanoparticles (MNPs), in order to achieve efficient and highly sensitive detection of single biomolecule recognition events, especially at extremely low analyte concentrations. ### Specific Problem Description 1. **Existing Challenges**: - The main challenge faced by existing biosensing technologies when detecting disease biomarkers or pathogens is to rapidly, quantitatively, and accurately detect target molecules in biological samples. - Although traditional fluorescence - labeling methods are widely used, they have a relatively high detection threshold (usually about \(10^4\) biomolecules are required to obtain a useful signal - to - noise ratio), and are easily affected by crosstalk and bleaching in the optical system. 2. **Limitations of Existing Technologies**: - Spin valves (SVs) have a weak signal strength when detecting smaller labeled magnetic moments, and due to their relatively low magnetoresistance change rate (MR ratio, about 10%), they require complex circuits for signal amplification, resulting in high power consumption. - Traditional methods using an external magnetic field to control the magnetization direction make the device design less compact and result in high power consumption. ### Solutions Proposed in the Paper The paper proposes a new method to enhance the sensitivity of MTJ biosensors by introducing hard - axis assist. Specifically: 1. **Hard - Axis Assist Methods**: - **Spin - injection torque induced by the spin - Hall effect (SHE)**: By applying a current, the SHE is used to generate a torque in the free layer along the hard - axis direction, thereby changing the magnetization direction of the free layer. - **Stress - induced effective - magnetic - field torque**: By applying a voltage to a piezoelectric material, strain is generated in the CoFeB - based MTJ structure, which in turn affects the magnetization direction of the free layer. 2. **Advantages**: - The detection sensitivity for a single magnetic bead is improved, especially at extremely low analyte concentrations. - No external magnetic field is required, making the device more compact and with lower energy consumption. - It can be used in highly sensitive, miniaturized, and low - power on - chip biodetection systems. ### Key Formulas - **Relationship between magnetic moment and angle**: \[ R = R_0+\Delta R\sin(\theta_F) \] where \(R_0\) and \(R_P\) are the resistances of the TMR sensor in orthogonal and parallel configurations respectively, \(\Delta R = R_P - R_0\), and \(\theta_F\) is the angle between the magnetization direction of the free layer and the z - axis. - **Relative magnetoresistance change**: \[ \text{Relative MR Change}=\frac{\Delta R_{\text{with}}-\Delta R_{\text{without}}}{\Delta R_{\text{without}}}=\frac{1}{2}[\sin(\theta_F^{\text{with}})-\sin(\theta_F^{\text{without}})] \] - **Torque caused by the spin - Hall effect**: \[ \tau_{\text{SHE}}=\hbar\eta_{\text{SO}}J_{\text{SHM}}m_F\times(m_F\times\hat{y}) \] where \(\eta_{\text{SO}}\) is the spin - orbit coupling constant, \(J_{\text{SHM}}\) is the current density through the spin - Hall - metal interface, and \(m_F\) is the normalized magnetic moment of the free layer. Through these improvements, the paper shows how to significantly improve the sensitivity of MTJ biosensors and provides new design ideas for future biodetection systems.