Detection of magnetic nanoparticles (MNPs) using spin current nano-oscillator (SCNO) biosensor: A frequency-based rapid, ultra-sensitive, magnetic bioassay

Renata Saha,Kai Wu,Diqing Su,Jian-Ping Wang
DOI: https://doi.org/10.48550/arXiv.1909.02204
2019-09-30
Abstract:This Letter is a micromagnetic simulation-based study on the GHz-frequency ferromagnetic resonances for the detection of magnetic nanoparticles (MNPs) using spin current nano-oscillator (SCNO) operating in precession mode as a spintronic biosensor. The magnetic stray fields from the MNPs in an antibody-antigen-MNP complex on the SCNO surface modify the ferromagnetic resonance peaks and generate measurable resonance peak shifts. Moreover, our results strongly indicate the position-sensitive behavior of the SCNO biosensor and ways to eradicate this effect to facilitate better bio-sensing performance. Additionally, a study has been made on how nanoparticles with different sizes can alter the SCNO device performance. This simulation-based study on the SCNO device shows a promise of frequency-based nano-biosensor with a sensitivity of detecting even a single MNP, even in presence of thermal noise.
Applied Physics,Biological Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a frequency - type biosensor based on spin - current nano - oscillator (SCNO) for the rapid and ultrasensitive detection of magnetic nanoparticles (MNPs). Specifically, the study explored the feasibility and performance of SCNO as a biosensor in detecting MNPs through micromagnetic simulation. The main problems include: 1. **Improving detection sensitivity**: Traditional magnetoresistive (MR) sensors are easily affected by high background noise at room temperature, which affects their sensitivity. This study aims to overcome this limitation through the frequency - type detection method. 2. **Position sensitivity**: The SCNO sensor is very sensitive to the position of MNP, which may affect its performance in practical applications. Therefore, the study explored how to reduce this position sensitivity to improve the consistency and reliability of the sensor. 3. **The influence of MNPs of different sizes on sensor performance**: The study also investigated how MNPs of different sizes change the performance of SCNO devices and proposed optimization schemes to ensure that the sensor can effectively detect MNPs of various sizes. 4. **Achieving the detection of a single MNP**: The study demonstrated the ability of the SCNO sensor to detect a single MNP in the presence of thermal noise, which is difficult for traditional sensors to achieve. ### Research background - **Limitations of existing technologies**: Traditional magnetic biosensing technologies such as giant magnetoresistive (GMR) sensors can detect MNPs, but are easily interfered by background noise at room temperature, resulting in a decrease in sensitivity. - **Advantages of frequency - type detection**: Compared with static magnetoresistive detection, frequency - type detection has the advantages of a wide linear response range and being unaffected by low - frequency 1/f noise, so it is more suitable for high - sensitivity biological detection. ### Main contributions - **Proposing SCNO as a frequency - type biosensor for the first time**: The feasibility of SCNO in detecting MNPs was verified through micromagnetic simulation. - **Analyzing in detail the influence of the position and size of MNPs on the performance of SCNO**: Providing a basis for optimizing sensor design and operating conditions. - **Demonstrating the detection ability of a single MNP**: Even in the presence of thermal noise, SCNO can detect a single MNP, proving its high sensitivity. In summary, the main objective of this paper is to develop a new frequency - type biosensor based on SCNO to achieve rapid and ultrasensitive detection of MNPs and solve some key problems in existing technologies.