Simultaneous determination of celecoxib, meloxicam, and rofecoxib using capillary electrophoresis with surfactant and application in drug formulations

Ya-Hui Hsieh,Shun-Jin Lin,Su-Hwei Chen
DOI: https://doi.org/10.1002/jssc.200500412
Abstract:A simple and selective CE using surfactant with UV detection is described for the simultaneous determination of selective cyclooxygenase-2 inhibitors, celecoxib, meloxicam, and rofecoxib. The simultaneous analysis of celecoxib, meloxicam, and rofecoxib was performed in Tris buffer (10 mM; pH 11) with 60 mM sodium octane-sulfonate and 20% ACN as an anionic surfactant and organic modifier, respectively. Under this condition, good separation with high efficiency and the required short analysis time is achieved. The linear ranges of the method for the determination of celecoxib, meloxicam, and rofecoxib were over 5-100 microg/mL; the detection limits at 200 nm (S/N = 3; injection 3.45 kPa, 5 s) were 2, 1, and 1 microg/mL, respectively. The small amount of sample required and the expeditiousness of the procedure allow content uniformity to be determined in individual pharmaceutical products.
What problem does this paper attempt to address?