Interplay between optical, viscous and elastic forces on an optically trapped Brownian particle immersed in a viscoelastic fluid

P. Domínguez-García,László Forró,Sylvia Jeney
DOI: https://doi.org/10.1063/1.4964405
2016-09-22
Abstract:We provide a detailed study of the interplay between the different interactions which appear in the Brownian motion of a micronsized sphere immersed in a viscoelastic fluid measured with optical trapping interferometry. To explore a wide range of viscous, elastic and optical forces, we analyze two different viscoelastic solutions at various concentrations, which provide a dynamic polymeric structure surrounding the Brownian sphere. Our experiments show that, depending of the fluid, optical forces, even if small, slightly modify the complex modulus at low frequencies. Based on our findings, we propose an alternative methodology to calibrate this kind of experimental set-up when non-Newtonian fluids are used. Understanding the influence of the optical potential is essential for a correct interpretation of the mechanical properties obtained by optically-trapped probe-based studies of biomaterials and living matter.
Soft Condensed Matter,Biological Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to understand and correct the influence of the optical potential on the measurement results when using optical tweezer technology to study the mechanical properties of complex fluids (especially non - Newtonian fluids). Specifically, the paper explores the interactions among the optical force, the viscous force and the elastic force when Brownian particles move in viscoelastic fluids. These force interactions will affect the accuracy of the fluid mechanical properties measured by optical tweezers, especially in the low - frequency region, where the optical force may change the complex modulus of the fluid. The main objective of the paper is to study the force situation of Brownian particles in known viscoelastic fluids. In the experiment, researchers used optical tweezers to capture microspheres and immersed them in polyethylene glycol (PEO) aqueous solutions or worm - like micelle solutions with different concentrations to analyze the interactions among the optical potential energy (assumed to be harmonic in the central region of the potential well), the random thermal force that generates Brownian motion, and the forces generated by the fluid. These forces can be studied through the complex modulus of the fluid (i.e., its elastic and viscous parts). To achieve this goal, the paper proposes a new calibration method for calibrating the experimental device when non - Newtonian fluids are used in optical tweezer interferometer experiments. This method does not rely on the active modulation of optical tweezers but uses long - term measurements to enable the probe to explore the boundaries of the trap. Through this method, the influence of optical tweezers on the measurement results can be evaluated more accurately, especially for the study of biological materials and living substances, which is crucial for correctly interpreting the mechanical properties obtained from the movement of optical tweezer probes.