Quantum Lock-in Force Sensing using Optical Clock Doppler Velocimetry

Ravid Shaniv,Roee Ozeri
DOI: https://doi.org/10.1038/ncomms14157
2016-02-28
Abstract:Force sensors are at the heart of different technologies such as atomic force microscopy or inertial sensing \cite{RMPforce2003, Rugar2004, YazdiIEEE}. These sensors often rely on the measurement of the displacement amplitude of mechanical oscillators under applied force. Examples for such mechanical oscillators include micro-fabricated cantilevers \cite{YazdiIEEE}, carbon nanotubes \cite{NanotubeForce} as well as single trapped ions \cite{Bollinger, Udem} . The best sensitivity is typically achieved when the force is alternating at the mechanical resonance frequency of the oscillator thus increasing its response by the mechanical quality factor. The measurement of low-frequency forces, that are below resonance, is a more difficult task as the resulting oscillation amplitudes are significantly lower. Here we use a single trapped $^{88}Sr^{+}$ ion as a force sensor. The ion is trapped in a linear harmonic trap, and is electrically driven at a frequency much lower than the trap resonance frequency. To be able to measure the small amplitude of motion we combine two powerful techniques. The force magnitude is determined by the measured periodic Doppler shift of an atomic optical clock transition and the Quantum Lock-in technique is used to coherently accumulate the phases acquired during different force half-cycles. We demonstrate force detection both when the oscillating force is phase-synchronized with the quantum lock-in sequence and when it is asynchronous and report frequency force detection sensitivity as low as $5.3\times10^{-19}\frac{\mathrm{N}}{\sqrt{\mathrm{Hz}}}$ .
Quantum Physics,Atomic Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is **how to accurately measure tiny forces in the low - frequency range**. Specifically, the author uses a single trapped strontium ion (\(^{88}\text{Sr}^+\)) as a force sensor, and combines the Doppler velocimetry technique of optical atomic clocks and the Quantum Lock - in technique to achieve high - sensitivity detection of low - frequency forces far below the mechanical resonance frequency. ### Main problem background 1. **Importance of force sensors**: - Force sensors have important applications in many fields, such as atomic force microscopy, inertial sensing, etc. - Traditional force sensors usually rely on the displacement of mechanical oscillators to estimate the applied force. 2. **Challenges**: - When the frequency of the force is far below the mechanical resonance frequency, the displacement amplitude of the oscillator decreases significantly, making the measurement difficult. - For forces far below the resonance frequency, it is difficult for traditional methods to maintain sufficient sensitivity. ### Solutions 1. **Experimental system**: - Use a single trapped \(^{88}\text{Sr}^+\) ion as a force sensor. - The ion is confined in a linear Paul trap and driven by an electric field to move at a frequency far below the trap resonance frequency. 2. **Key techniques**: - **Doppler velocimetry technique of optical atomic clocks**: Determine the magnitude of the force by measuring the periodic Doppler shift caused by the ion motion. - **Quantum Lock - in technique**: Improve the signal - to - noise ratio and measurement sensitivity by coherently accumulating the phases obtained within different force half - cycles. 3. **Experimental results**: - The experiment demonstrates the ability to detect oscillating forces in both phase - synchronized and non - synchronized cases. - The measured force detection sensitivity reaches \(5.3\times 10^{-19}\, \text{N}/\sqrt{\text{Hz}}\). ### Formula summary - The equation of motion of the ion in the steady state is: \[ x(t)=x_0\cos(2\pi f_m t)=\frac{F_0}{4\pi^2(f_t^2 - f_m^2)m_{\text{ion}}}\cos(2\pi f_m t) \] where: - \(F_0\) is the amplitude of the force, - \(m_{\text{ion}} = 87.9\, \text{amu}\) is the mass of the ion, - \(f_m = 1.013\, \text{kHz}\) is the driving frequency of the force, - \(f_t = 1.13\, \text{MHz}\) is the resonance frequency of the trap. - The super - position phase evolution formula: \[ \varphi_{\text{clk}}(t)=2\pi x_0\sqrt{\frac{2}{\lambda}}[\sin(2\pi f_m t+\xi)-\sin(\xi)] \] - The quantum lock - in phase formula: \[ \varphi_{\text{clk}}=\frac{4\pi x_0\sqrt{2}}{\lambda}\cos\left(\frac{2\pi f_n\tau+\xi + n\pi}{2}\right)\frac{\cos(2\pi f\tau)\sin\left(\frac{2\pi f_n\tau - n\pi}{2}\right)}{\sin^2(\pi f\tau)} \] ### Conclusion By combining the Doppler velocimetry technique of optical atomic clocks and the Quantum Lock - in technique, this research successfully achieves high - sensitivity measurement of low - frequency forces, with a sensitivity reaching \(5.3\times 10^{-19}\, \text{N}/\sqrt{\text{Hz}}\). This result provides new methods and technical means for sensitive detection of electric fields and other weak forces.