Evaluation of various Deformable Image Registrations for Point and Volume Variations

Su Chul Han,Sang Hyun Choi,Seungwoo Park,Soon Sung Lee,Haijo Jung,Mi-Sook Kim,Hyung Jun Yoo,Young Hoon Ji,Chul Young Yi,Kum Bae Kim
DOI: https://doi.org/10.48550/arXiv.1503.03622
2015-03-12
Abstract:The accuracy of deformable image registration (DIR) has a significant dosimetric impact in radiation treatment planning. We evaluated accuracy of various DIR algorithms using variations of the deformation point and volume. The reference image (Iref) and volume (Vref) was first generated with virtual deformation QA software (ImSimQA, Oncology System Limited, UK). We deformed Iref with axial movement of deformation point and Vref depending on the types of deformation that are the deformation1 is to increase the Vref (relaxation) and the deformation 2 is to decrease . The deformed image (Idef) and volume (Vdef) acquired by ImSimQA software were inversely deformed to Iref and Vref using DIR algorithms. As a result, we acquired deformed image (Iid) from Idef and volume (Vid) from Vdef. The DIR algorithms were the Horn Schunk optical flow (HS), Iterative Optical Flow (IOF), Modified Demons (MD) and Fast Demons (FD) with the Deformable Image Registration and Adaptive Radiotherapy Toolkit (DIRART) of MATLAB. The image similarity between Iref and Iid was calculated using the metrics that were Normalized Mutual Information (NMI) and Normalized Cross Correlation (NCC). When moving distance of deformation point was 4 mm, the value of NMI was above 1.81 and NCC was above 0.99 in all DIR <a class="link-external link-http" href="http://algorithms.When" rel="external noopener nofollow">this http URL</a> the Vref increased or decreased about 12%, the difference between Vref and Vid was within 5% regardless of the type of <a class="link-external link-http" href="http://deformation.The" rel="external noopener nofollow">this http URL</a> value of Dice Similarity Coefficient (DSC) was above 0.95 in deformation1 except for the MD algorithm. In case of deformation 2, that of DSC was above 0.95 in all DIR algorithms. The Idef and Vdef have not been completely restored to Iref and Vref and the accuracy of DIR algorithms was different depending on the degree of deformation. Hence, the performance of DIR algorithms should be verified for the desired applications.
Medical Physics
What problem does this paper attempt to address?
This paper aims to evaluate the accuracy of different Deformable Image Registration (DIR) algorithms under the conditions of point and volume changes. Specifically, the researchers used the ImSimQA (Virtual Deformation Quality Assurance Software) to generate reference images and volumes, and then tested the performance of four intensity - based DIR algorithms (Horn - Schunck optical flow (HS), Iterative Optical Flow (IOF), Modified Demons algorithm (MD), and Fast Demons algorithm (FD)) by changing the position of deformation points and volume changes. The accuracy of these algorithms was evaluated by image similarity (measured using Normalized Mutual Information (NMI) and Normalized Cross - Correlation (NCC)) and volume overlap degree (measured using Dice Similarity Coefficient (DSC)). The main objectives of the paper are: 1. **Evaluate the performance of DIR algorithms under different deformation conditions**: The researchers simulated the deformation situations that may occur in tumors and normal tissues during multi - fraction radiotherapy in the clinic by changing the position of deformation points and volume changes, so as to evaluate the performance of DIR algorithms. 2. **Provide a quantitative analysis of the accuracy of DIR algorithms**: Quantify the performance of different DIR algorithms in processing deformed images through specific indicators such as NMI, NCC, and DSC, so as to provide references for the application in Adaptive Radiotherapy (ART). The research results show that as the degree of deformation increases, the image similarity decreases; when the reference volume increases or decreases by about 12%, the difference between the deformed volume and the reference volume is kept within ±5%. In addition, different DIR algorithms show different performances in dealing with specific types of deformation, which emphasizes the importance of verifying the performance of DIR algorithms in practical applications.