A Multi-chain Measurements Averaging TDC Implemented in a 40 nm FPGA

Qi Shen,Shubin Liu,Binxiang Qi,Qi An,Shengkai Liao,Chengzhi Peng,Weiyue Liu
DOI: https://doi.org/10.1109/RTC.2014.7097550
2014-06-15
Abstract:A high precision and high resolution time-to-digital converter (TDC) implemented in a 40 nm fabrication process Virtex-6 FPGA is presented in this paper. The multi-chain measurements averaging architecture is used to overcome the resolution limitation determined by intrinsic cell delay of the plain single tapped-delay chain. The resolution and precision are both improved with this architecture. In such a TDC, the input signal is connected to multiple tapped-delay chains simultaneously (the chain number is M), and there is a fixed delay cell between every two adjacent chains. Each tapped-delay chain is just a plain TDC and should generate a TDC time for a hit input signal, so totally M TDC time values should be got for a hit signal. After averaging, the final TDC time is obtained. A TDC with 3 ps resolution (i.e. bin size) and 6.5 ps precision (i.e. RMS) has been implemented using 8 parallel tapped-delay chains. Meanwhile the plain TDC with single tapped-delay chain yields 24 ps resolution and 18 ps precision.
Instrumentation and Detectors,High Energy Physics - Experiment
What problem does this paper attempt to address?
This paper aims to solve the problems of time - to - digital converters (TDCs) in terms of high precision and high resolution. Specifically, traditional FPGA - based time - to - digital converters are limited by their inherent cell delays, resulting in insufficient resolution and precision. To overcome this limitation, the paper proposes a multi - chain measurements averaging architecture. By using multiple tapped - delay chains simultaneously, the resolution and precision of the TDC are improved. The paper mentions that the resolution and precision of the traditional single - chain delay TDC are 24 picoseconds (ps) and 18 picoseconds (ps) respectively. After adopting the multi - chain measurements averaging architecture, the resolution can be improved to 3 picoseconds (ps) and the precision can be improved to 6.5 picoseconds (ps), which significantly enhances the performance of the TDC. Through this multi - chain measurements averaging method, each input signal will be connected to multiple delay chains, and each delay chain will generate a TDC time value. These time values are averaged to obtain the final TDC time. This method not only improves the resolution and precision, but also does not increase the dead time because multiple links work simultaneously. In conclusion, the main goal of this paper is to achieve a TDC with higher precision and higher resolution through the multi - chain measurements averaging architecture, so as to meet the application requirements with extremely high requirements for time measurement precision.