Intracavity trace molecular detection with a broadband mid-IR frequency comb source

Magnus W. Haakestad,Tobias P. Lamour,Nick Leindecker,Alireza Marandi,Konstantin L. Vodopyanov
DOI: https://doi.org/10.1364/JOSAB.30.000631
2013-01-23
Abstract:Ultrasensitive detection of methane, isotopic carbon dioxide, carbon monoxide, formaldehyde, acetylene and ethylene is performed in the spectral range 2.5 - 5 \mu m using intracavity spectroscopy in broadband optical parametric oscillators (OPOs). The OPOs were operated near degeneracy and synchronously pumped either by a mode-locked erbium (1560 nm) or thulium (2050 nm) fiber laser. A large instantaneous bandwidth of up to 800 cm$^{-1}$ allows for simultaneous detection of several gases. We observe an effective path length enhancement due to coherent interaction inside the OPO cavity and achieve part-per-billion sensitivity levels. The measured spectral shapes are in good agreement with a model that takes into account group delay dispersion across the broad OPO frequency band.
Optics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a method for ultrasensitive detection of trace gases, especially in the mid - infrared (mid - IR) band (2.5 – 5 µm). Specifically, the research team uses a broadband mid - infrared frequency - comb light source to perform molecular detection in an optical parametric oscillator (OPO) cavity. This method can detect multiple gases simultaneously and has reached a sensitivity at the parts - per - billion (ppb) level. ### Main problems and goals 1. **Ultrasensitive gas detection**: Achieve ultrasensitive detection of gases such as methane, isotopic carbon dioxide, carbon monoxide, formaldehyde, acetylene and ethylene in the mid - infrared band. 2. **Simultaneous detection of multiple gases**: Realize the simultaneous detection of multiple gases through broadband light sources and Fourier transform methods. 3. **Improve detection sensitivity**: Utilize the coherent interaction in the OPO cavity to increase the effective path length, thereby improving the detection sensitivity. 4. **Model verification**: Verify the consistency of spectral shape and phase change through comparison between experimental measurements and theoretical models. ### Key points of the solution - **Broadband mid - infrared frequency - comb light source**: Use a synchronously pumped optical parametric oscillator (OPO), pumped by a mode - locked erbium - fiber laser (1560 nm) or a thulium - fiber laser (2050 nm), to generate broadband mid - infrared light. - **Intracavity spectroscopy**: Use the OPO cavity itself as an enhancement cavity, and inject gas directly into the OPO cavity or use an intracavity gas cell with a Brewster window to increase the effective path length. - **Theoretical modeling**: Consider the effects of intracavity dispersion and molecular absorption, and establish a theoretical model to explain the experimental results. ### Experimental results - **Methane detection**: Achieved high - precision detection of 8.5 ppm methane, with an estimated detection limit of 1.7 ppb. - **Formaldehyde detection**: Through the intracavity gas cell, achieved the detection of 100 ppm formaldehyde, with the sensitivity increased by about 6 times and the detection limit of about 0.31 ppm. - **Simultaneous detection of multiple gases**: Successfully detected 3.8 ppm acetylene and 1.4 ppm methane simultaneously. Through these methods, the research team has demonstrated the potential of broadband mid - infrared frequency - comb light sources combined with intracavity spectroscopy in ultrasensitive gas detection, and has broad application prospects especially in fields such as environmental monitoring, medical diagnosis and industrial process monitoring.