Preparation of an emittance transfer experiment

C. Xiao,O. Kester,L. Groening,H. Leibrock,M. Maier
DOI: https://doi.org/10.48550/arXiv.1212.2034
2012-12-10
Abstract:Flat beams feature unequal emittances in the horizontal and vertical phase space. Those beams were created successfully in lepton machines. Although a number of applications will profit also from flat hadron beams, to our knowledge they have never been created systematically. Multi-turn injection schemes, spectrometers, and colliders will directly benefit from those beams. The present paper covers the preparation of the experimental proof of principle for flat hadron beam creation in a beam transport section. Detailed simulations of the experiment, based on charge state stripping inside of a solenoid [L. Groening, Phys. Rev. ST Accel. Beams 14, 064201 (2011)], are performed. The matrix formalism was benchmarked with tracking through three-dimensional magnetic field maps of solenoids. An error analysis targeting at investigation of the impact of machine errors on the round-to-flat beam transformation has been performed. The remarkable flexibility of the set-up w.r.t. decoupling is addressed, as it can provide an one-knob tool to set the horizontal and vertical emittance partitioning. Finally, the status of hardware design and production is given.
Accelerator Physics
What problem does this paper attempt to address?
This paper aims to solve the problem of how to achieve the conversion from a circular ion beam to a flat ion beam while keeping the full six - dimensional emittance unchanged. Specifically, the research focuses on experimentally verifying a new method that can create flat hadron beams with different horizontal and vertical phase - space emittances in the transmission line. This method is very beneficial for improving the performance of applications such as multi - turn injection schemes, spectrometers, and colliders. ### Background of the Paper - **Presentation of the Problem**: Normally, in principle, the beam is circular without coupling between planes, and its root - mean - square emittance and characteristic emittance in the two transverse planes are equal. Therefore, any transverse circular - to - flat conversion requires a change in the characteristic emittance of the beam, which requires a non - symplectic transformation. - **Existing Technologies**: Flat beams have been successfully created in electron machines, but as far as the author knows, flat hadron beams have not been systematically created yet. Existing methods mainly rely on placing a charge - state stripper inside the axial magnetic field region to achieve non - symplectic transformation. ### Experimental Setup - **Experimental Design**: The experimental setup includes two quadrupole twins, a solenoid with a stripping foil, a quadrupole triplet, an inclined quadrupole triplet, another quadrupole triplet, a current transformer, and a transverse emittance measurement unit. - **Key Components**: - **Solenoid**: It is used to create a non - symplectic transformation, causing coupling between the transverse planes. - **Stripping Foil**: Placed in the center of the solenoid, it is used to change the rigidity of the beam. - **Inclined Quadrupole Magnet**: It is used to remove the coupling and achieve the decoupling of the beam. ### Theoretical Analysis - **Non - symplectic Transformation**: By placing a stripping foil inside the solenoid, a non - symplectic transformation can be created, thereby changing the characteristic emittance of the beam. - **Decoupling Process**: Using the decoupling section composed of inclined quadrupole magnets, the coupling between the transverse planes can be removed, and the beam can be restored to the desired emittance distribution. ### Simulation and Verification - **Simulation Method**: Simulation is carried out using matrix form and three - dimensional magnetic field maps to verify the effectiveness of the non - symplectic transformation and the decoupling process. - **Error Analysis**: The influence of machine errors (such as gradient fluctuations and rotation of quadrupole magnets) on the decoupling performance is studied, and it is found that these errors have a relatively small impact on the decoupling performance. ### Conclusions and Prospects - **Conclusions**: The experimental setup can effectively achieve the circular - to - flat beam conversion, and the decoupling performance is insensitive to the change of the solenoid magnetic field intensity within a certain range. - **Prospects**: Currently, the experimental setup is under construction, and experiments are planned to be carried out in 2014. This research result will help improve the performance of the accelerator chain, especially in applications such as multi - turn injection and high - luminosity collision. ### Formula Summary - **Characteristic Emittance**: \[ \epsilon_1, \epsilon_2=\frac{1}{2} \sqrt{-\text{tr}(CJ)^{2} \pm \sqrt{\text{tr}^{2}(CJ)^{2}-16 \det(C)}} \] - **Focusing Intensity**: \[ k = \frac{B}{2(B\rho)} \] - **Decoupling Parameter**: \[ t=\frac{\epsilon_x \epsilon_y}{\epsilon_1 \epsilon_2}-1 \] These formulas are used in the paper to describe and analyze the characteristic emittance change and decoupling process of the beam.