Abstract:In spin values the damping parameters of the free layer are determined non-locally by the entire magnetic configuration. In a dual spin valve structure that comprises a free layer embedded between two pinned layers, the spin pumping mechanism, in combination with the angular momentum conservation, renders the tensor-like damping parameters tunable by varying the interfacial and diffusive properties. Simulations based on the Landau-Lifshitz-Gilbert phenomenology for a macrospin model are performed with the tensor-like damping and the relaxation time of the free layer magnetization is found to be largely dependent on while tunable through the magnetic configuration of the source-drain magnetization.
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: in the Dual Spin Valve (DSV) structure, how to achieve tunability of the free - layer magnetization relaxation time by regulating the magnetic configuration and material properties. Specifically, the author focuses on the non - local dependence of the Gilbert damping parameter in DSV and its performance in tensor form.
### Problem Background
In the spin - valve structure, the damping parameter of the free layer is usually considered as a scalar, but in more complex systems, such as the dual - layer spin valve, the damping parameter is actually a tensor. This tensor - form damping parameter depends on the configuration of the entire magnetic structure and can be regulated by changing the interface and diffusion properties. This phenomenon is closely related to the spin - pumping mechanism and angular - momentum conservation.
### Research Objectives
1. **Analyze the origin of the damping tensor**: Derive an explicit analytical expression of the damping tensor by combining angular - momentum conservation and magneto - electronic circuit theory.
2. **Study the dependence of the damping tensor**: Explore how the damping tensor depends on the magnetic configuration and material properties of the entire DSV.
3. **Simulate the magnetization relaxation time**: Verify the change of the free - layer magnetization relaxation time under different magnetic configurations by numerically simulating the Landau - Lifshitz - Gilbert (LLG) equation.
### Main Findings
- **Analytical expression of the damping tensor**: The author has derived the specific form of the damping tensor, which is determined by the magnetic configuration and material properties of the entire DSV.
- **Tunability of the magnetization relaxation time**: By adjusting the magnetization directions at the source and drain ends, the magnetization relaxation time of the free layer can be significantly changed. For example, in the low - field case, switching from the (z,z) configuration to the (y,y) configuration can shorten the relaxation time by about 21%; in the high - field case, this improvement is more significant, reaching nearly 31%.
### Conclusion
This research provides a new approach for designing and controlling the magnetization dynamics in spintronic devices. By regulating the magnetization configuration at the source and drain ends, the magnetization relaxation time of the free layer can be effectively adjusted, thereby optimizing device performance.
### Formula Summary
1. **General expression of the damping tensor**:
\[
\vec{\alpha} = \frac{\hbar g^{\uparrow\downarrow}_F}{4\pi} \left( D_L^{is} + D_R^{is} + D_L^{an} \hat{A}_{L,an} + D_R^{an} \hat{A}_{R,an} \right)
\]
2. **Expression of the exchange torque**:
\[
T = M \times \vec{\alpha} \cdot \dot{M}
\]
3. **Magnetization relaxation equation**:
\[
\frac{dM}{dt} = -\gamma M \times H_{eff} + \alpha_0 M \times \frac{dM}{dt} + \frac{\gamma}{\mu_0 M_s V} M \times \vec{\alpha} \cdot \frac{dM}{dt}
\]
These formulas show how to influence the magnetization relaxation process in the spin valve by regulating the magnetic configuration and material properties.