Study of the moving offset characteristics of multi-loop moving coil linear compressor

Hongyue Chen,Xianyang Liu,Xianfeng Zou,Zhangquan Lv,Wei Li,Chen Chen
DOI: https://doi.org/10.1016/j.ijrefrig.2021.11.001
IF: 4.14
2022-01-01
International Journal of Refrigeration
Abstract:In this paper, a novel Multi-loop Moving Coil Large Output Volume Linear Compressors (M-MC-l-LC, Max 381.3cc) is proposed. A Co-core Bilateral Reverse Coil(CBRC) and a new Halbach permanent magnet ring array structure are proposed for the first time and applied to the development of prototype. The M-MC-l-LC electromagnetic force calculation equation is derived, the moving offset characteristics under different pressure ratios are studied, and a mathematical model that can reflect the moving offset law is established. Introduction the DC offset control method to solve the moving offset problem. Development the M-MC-l-LC prototype and construction a dynamic test rig for compressors. Experimental results show that increasing DC voltage countervails the moving offset and significantly increases the discharge pressure. The theoretical error of moving offset is within 8% and the mechanical efficiency of prototype is approximately 11.4% higher than that of the conventional compressor. The results of study have theoretical and practical implications for other linear compression moving offset analysis and accurate regulation of refrigeration capacity.
engineering, mechanical,thermodynamics
What problem does this paper attempt to address?