Membrane electrode assembly simulation of anion exchange membrane water electrolysis

Khaled Lawand,Suhas Nuggehalli Sampathkumar,Zoé Mury,Jan Van Herle
DOI: https://doi.org/10.1016/j.jpowsour.2023.234047
IF: 9.2
2024-01-10
Journal of Power Sources
Abstract:Anion exchange membrane water electrolysis (AEMWE) offers a green hydrogen production method that eliminates the need for platinum group metals (PGM) as electrocatalysts. This study employs a COMSOL® 6.0 model to simulate a 1x1 cm 2 Ni fibre − Raney® Ni || X37-50RT || NiFe 2 O 4 − SS316L fibre AEMWE membrane electrode assembly (MEA). The membrane is set at a thickness of 60μm , while the anodic and cathodic porous transport layers (PTL) are modelled with a thickness of 370μm , each having an average porosity of 0.70. The half − cell overpotentials are experimentally measured to validate the half − cell model in a three − electrode setup consisting of (working electrode) || AGAR-Ag/AgCl || Pt − wire (counter electrode). Two freshly prepared MEAs validated the (i) base case and (ii) sensitivity analysis models. The base case model validated the MEA results at 20 °C and 1 atm in 1M KOH electrolyte feed at 1.56 ml min −1 cm −2 . The five parameters studied with the sensitivity analysis revealed the most influential parameters based on area-specific resistance (ASR) change in the following order (+ and − indicate increase and decrease in ASR, respectively): KOH concentration ( − 97%), membrane thickness (+ 9%), temperature ( − 4%), cathode feed type ( <+ 0.5%), and KOH flow rate ( >− 0.5%).
energy & fuels,materials science, multidisciplinary,electrochemistry,chemistry, physical
What problem does this paper attempt to address?