Mapping Injection Order Messages to Health Level 7 Fast Healthcare Interoperability Resources to Collate Infusion Pump Data

Shunsuke Doi,Shinichiroh Yokota,Yugo Nagae,Koichi Takahashi,Mitsuhiro Aoki,Kazuhiko Ohe
DOI: https://doi.org/10.1055/s-0043-1776699
IF: 2.762
2024-01-04
Applied Clinical Informatics
Abstract:Background When administering an infusion to a patient, it is necessary to verify that the infusion pump settings are in accordance with the injection orders provided by the physician. However, the infusion rate entered into the infusion pump by the health care provider cannot be automatically reconciled with the injection order information entered into the electronic medical records (EMRs). This is because of the difficulty in linking the infusion rate entered into the infusion pump by the health care provider with the injection order information entered into the EMRs. Objectives This study investigated a data linkage method for reconciling infusion pump settings with injection orders in the EMRs. Methods We devised and implemented a mechanism to convert injection order information into the Health Level 7 Fast Healthcare Interoperability Resources (FHIR), a new health information exchange standard, and match it with an infusion pump management system in a standard and simple manner using a REpresentational State Transfer (REST) application programming interface (API). The injection order information was extracted from Standardized Structured Medical Record Information Exchange version 2 International Organization for Standardization/technical specification 24289:2021 and was converted to the FHIR format using a commercially supplied FHIR conversion module and our own mapping definition. Data were also sent to the infusion pump management system using the REST Web API. Results Information necessary for injection implementation in hospital wards can be transferred to FHIR and linked. The infusion pump management system application screen allowed the confirmation that the two pieces of information matched, and it displayed an error message if they did not. Conclusion Using FHIR, the data linkage between EMRs and infusion pump management systems can be smoothly implemented. We plan to develop a new mechanism that contributes to medical safety through the actual implementation and verification of this matching system. This article does not contain any studies with human or animal subjects performed by any of the authors. Received: 14 April 2023 Accepted: 02 October 2023 Article published online: 03 January 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
medical informatics
What problem does this paper attempt to address?