"Newly Proposed Approach For Assessing Dyspnea: Pilot Study To Determine Feasibility, Safety And What Clinical Information From A Dual Treadmill And Dobutamine Stress Echocardiogram Protocol"

Khalid Sawalha,Carlos M. Nieves-La Cruz,Alvaro Aranda,Angel Lopez-Candales
DOI: https://doi.org/10.1016/j.cardfail.2023.10.078
IF: 6.592
2024-01-01
Journal of Cardiac Failure
Abstract:Background Stress echocardiography (SE) is a routinely validated useful imaging modality for the assessment and/or exclusion of coronary artery disease. However, the utility of SE has has become an established method to evaluate a wide spectrum of nonischemic hemodynamic clinical entities. Even though chest pain represents the most common requesting symptom; dyspnea evaluation is becoming a frequent referring complaint. Dyspnea assessment can be both challenging and frustrating. Consequently, we designed a pilot study to determine feasibility, safety and amount of clinical Information derived from a new protocol Methods For this pilot study we included 15 outpatients (mean age 59 ± 16 years, 4 males with a body surface area of 1.9 ± 0.2 m2) referred with dyspnea and exercise intolerance. A low-level treadmill (STE) was performed first to assess hemodynamic responses to exercise. After a 15-minute rest, dobutamine infusion (DSE) was administered to exclude CAD (Figure 1). Results Even though the time to complete both tests is usually longer than that for either STE or DSE; both were well tolerated and completed by all patients without complications. Though, most patient were only able to complete a modified Bruce protocol; right (RV) and left ventricular (LV) systolic function, mitral valve inflow and pulmonary artery systolic pressures increased significantly. (Table 1) Completion of DSE was useful to exclude CAD and was most useful to determine RV functional reserve (Table 1). Conclusions To the best of our knowledge, this is the first time that this dual SE protocol is performed in tandem. We showed that this protocol is both feasible and safe while providing useful hemodynamic information, during the STE portion, even if patients have a limited functional capacity. The DSE potion allows better for examination of RV function, a prime determinant of exercise tolerance, as well as exclusion of CAD. This dual protocol appears to provide more comprehensive clinical information; particularly in patients suffering from dyspnea and exercise intolerance while avoiding diagnostic dilemmas as well as reducing preauthorization delays.
cardiac & cardiovascular systems
What problem does this paper attempt to address?