Safety of Concomitant Cortical and Thalamic Stereoencephalography Explorations in Patients With Drug-Resistant Epilepsies

Jasmine L. Hect,Arka N. Mallela,Michael Pupi,Austin Anthony,David Fogg,Jonathan Ho,Anna L. Slingerland,Naoki Ikegaya,Hussam Abou-Al-Shaar,Thandar Aung,Jorge Gonzalez-Martinez
DOI: https://doi.org/10.1227/neu.0000000000002919
IF: 5.315
2024-03-22
Neurosurgery
Abstract:BACKGROUND AND OBJECTIVES: Intracranial electrophysiology of thalamic nuclei has demonstrated involvement of thalamic areas in the propagation of seizures in focal drug-resistant epilepsy. Recent studies have argued that thalamus stereoencephalography (sEEG) may aid in understanding the epileptogenic zone and treatment options. However, the study of thalamic sEEG-associated hemorrhage incidence has not been investigated in a cohort study design. In this article, we present the largest retrospective cohort study of sEEG patients and compare hemorrhage rates between those with and without thalamic sEEG monitoring. METHODS: Retrospective chart review of clinical and epilepsy history, electrode implantation, rationale, and outcomes was performed for 76 patients (age 20-69 years) with drug-resistant epilepsy who underwent sEEG monitoring at our institution (2019-2022). A subset of 38% of patients (n = 30) underwent thalamic monitoring of the anterior thalamic nucleus (n = 14), pulvinar nucleus (n = 25), or both (n = 10). Planned perisylvian orthogonal sEEG trajectories were extended to 2- to 3-cm intraparenchymally access thalamic area(s).The decision to incorporate thalamic monitoring was made by the multidisciplinary epilepsy team. Statistical comparison of hemorrhage rate, type, and severity between patients with and without thalamic sEEG monitoring was made. RESULTS: Our approach for thalamic monitoring was not associated with local intraparenchymal hemorrhage of thalamic areas or found along extended cortical trajectories, and symptomatic hemorrhage rates were greater for patients with thalamic coverage (10% vs 0%, P = .056), although this was not found to be significant. Importantly, patients with perisylvian electrode trajectories, with or without thalamic coverage, did not experience a higher incidence of hemorrhage ( P = .34). CONCLUSION: sEEG of the thalamus is a safe and valuable tool that can be used to interrogate the efficacy of thalamic neuromodulation for drug-resistant epilepsy. While patients with thalamic sEEG did have higher incidence of hemorrhage at any monitoring site, this finding was apparently not related to the method of perisylvian implantation and did not involve any trajectories targeting the thalamus.
surgery,clinical neurology
What problem does this paper attempt to address?