Impact of relative humidity, temperature difference, and surface type on humid air condensation heat transfer

Parisa Dehghani,Hesam Ami Ahmadi,Seyed Mostafa Hosseinalipour,Habibollah Akbari
DOI: https://doi.org/10.1016/j.ijthermalsci.2024.109168
IF: 4.779
2024-06-02
International Journal of Thermal Sciences
Abstract:The primary purpose of the current study is to experimentally explore how humid air condenses on hydrophilic (Copper) and hydrophobic (Copper coated by Teflon) surfaces under specific operating conditions, including relative humidities (RH) ranging from 80 % to 96 % and temperature differences (DT) ranging from 4 °C to 10 °C over180 min. This study uses the design of the experiment (DOE), specifically the Response Surface Methodology (RSM), to evaluate and propose correlation relationships between heat transfer coefficient (HTC) and environmental parameters for each surface. The results have been analyzed, and it has been shown that the heat transfer coefficient on the hydrophilic surface has decreased with time due to the change of the condensation regime from dropwise to filmwise. Moreover, with an increase in temperature difference and relative humidity, the change of condensation regime occurs in a shorter time, and the effect of temperature difference is greater than relative humidity. This heat transfer drop and regime change has been observed on the hydrophobic surface only in relative humidity of 96 % and temperature difference of 10 °C. In this case, the highest average heat transfer coefficient over a 180-min testing period was calculated, equal to 1.18. Notably, it is only under these conditions that the average heat transfer coefficient for the hydrophobic surface is more than that of the hydrophilic surface. The research findings indicate that temperature difference, relative humidity, and surface type notably influence the heat transfer coefficient. According to the duration of the experiment, comparing the effectiveness of each of the parameters revealed that the temperature difference had the most substantial impact—approximately 16 % greater than relative humidity and 53 % greater than surface type.
engineering, mechanical,thermodynamics
What problem does this paper attempt to address?