Simulated Reduced-Count Whole-Body FDG PET: Evaluation in Children and Young Adults Imaged on a Digital PET Scanner

Samuel Brady,Nadeen Abu Ata,Yinan Li,Joseph MacLean,Bin Zhang,Vinicius P. V. Alves,Susan E. Sharp,Andrew T. Trout
DOI: https://doi.org/10.2214/ajr.22.27894
2022-12-01
American Journal of Roentgenology
Abstract:<b>BACKGROUND.</b> Digital PET scanners with increased sensitivity may allow shorter scan acquisition times or reductions in administered radiopharmaceutical activities. <b>OBJECTIVE.</b> The purpose of this study was to evaluate in children and young adults the impact of shorter simulated acquisition times on the quality of whole-body FDG PET images obtained using a digital PET/CT system. <b>METHODS.</b> This retrospective study included 27 children and young adults (nine male and 18 female patients) who underwent clinically indicated whole-body FDG PET/CT examinations performed using a 25-cm axial FOV PET/CT system at 90 s per bed position (expressed hereafter as seconds per bed). Raw list-mode data were reprocessed to simulate acquisition times of 60, 55, 50, 45, 40, and 30 s/bed. Three radiologists independently reviewed reconstructed images and assigned Likert scores for lesion conspicuity, normal structure conspicuity, image quality, and image noise. A separate observer recorded the SUV<sub>max</sub>, SUV<sub>mean</sub>, and SD of the SUV (SUV<sub>SD</sub>) for liver, thigh, and the most FDG-avid lesion. The SUV<sub>SD</sub>/SUV<sub>mean</sub> (the SUV<sub>SD</sub> divided by the SUV<sub>mean</sub>) was calculated as a surrogate of image noise. ANOVA, the Friedman test, and the Dunn test were used to compare qualitative measures (combining reader scores) and SUV measurements. <b>RESULTS.</b> The mean patient age was 10.8 ± 8.3 (SD) years, mean BMI was 18.7 ± 2.9, and mean administered FDG activity was 4.44 ± 0.37 MBq/kg (0.12 ± 0.01 mCi/kg). No qualitative measure showed a significant difference versus 90 s/bed for the simulated acquisition at 60 s/bed (all <i>p</i> &gt; .05). Significant differences (all <i>p</i> &lt; .05) versus 90 s/bed were observed for lesion conspicuity at at most 40 s/bed, conspicuity of normal structures and overall image quality at at most 45 s/bed, and image noise at at most 55 s/bed. SUV<sub>mean</sub> was not significantly different from 90 s/bed for any site for any reduced-count simulation (all <i>p</i> &gt; .05). SUV<sub>SD</sub>/SUV<sub>mean</sub> and SUV<sub>max</sub> showed gradual increases with decreasing acquisition times and were significantly different from 90 s/bed only for liver at 60 s/bed (for SUV<sub>max</sub>: 1.00 ± 0.00 vs 1.05 ± 0.03, <i>p</i> = .02; for SUV<sub>SD</sub>/SUV<sub>mean</sub>: 0.09 ± 0.02 vs 0.11 ± 0.02, <i>p</i> = .04). <b>CONCLUSION.</b> Favorable findings for the simulated acquisition at 60 s/bed suggest that, in children and young adults who undergo imaging performed using a 25-cm FOV digital PET scanner, acquisition time or administered FDG activity may be decreased by approximately 33% from the clinical standard without significantly impacting image quality. <b>CLINICAL IMPACT.</b> A 25-cm axial FOV digital scanner may allow FDG PET/CT examinations to be performed with reduced radiation exposure or faster scan acquisition times.
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?