Compensation of mounting error in in-situ wear measurement during gear pitting test

Jiachun Lin,Hanxiao Li,Peng Wang,Ningzhi Li,Zhaoyao Shi,Ulf Olofsson
DOI: https://doi.org/10.1016/j.measurement.2022.110808
IF: 5.6
2022-03-01
Measurement
Abstract:A profilometer can be used to monitor the tooth surface topography evolution during gear pitting tests. Due to the mounting relationship variation between the instrument and the gear, the tooth profile’s measurement position deviation from its theoretical location will introduce a measurement error. In this study, the tooth profile measurement error introduced by mounting using a tactile profilometer was theoretically analysed and experimentally confirmed as a fish shape. A mounting error compensation method based on projection onto the perpendicular plane to the gear’s datum axis was proposed. The results show that the fish-shaped tooth profile measurement error can be effectively compensated, benefitting the evaluation of the gear tooth surface wear during gear pitting tests.
engineering, multidisciplinary,instruments & instrumentation
What problem does this paper attempt to address?