U-shaped, double-tapered, fiber-optic sensor for effective biofilm growth monitoring

Nianbing Zhong,Mingfu Zhao,Yishan Li
DOI: https://doi.org/10.1364/boe.7.000335
IF: 3.4
2016-01-07
Biomedical Optics Express
Abstract:To monitor biofilm growth on polydimethylsiloxane in a photobioreactor effectively, the biofilm cells and liquids were separated and measured using a sensor with two U-shaped, double-tapered, fiber-optic probes (Sen. and Ref. probes). The probes' Au-coated hemispherical tips enabled double-pass evanescent field absorption. The Sen. probe sensed the cells and liquids inside the biofilm. The polyimide-silica hybrid-film-coated Ref. probe separated the liquids from the biofilm cells and analyzed the liquid concentration. The biofilm structure and active biomass were also examined to confirm the effectiveness of the measurement using a simulation model. The sensor was found to effectively respond to the biofilm growth in the adsorption through exponential phases at thicknesses of 0-536 μm.
radiology, nuclear medicine & medical imaging,biochemical research methods,optics
What problem does this paper attempt to address?