Recent progress of avalanche photodiodes in high-resolution X-rays and Gamma-rays detection

J.Kataoka,T.Saito,Y.Kuramoto,T.Ikagawa,Y.Yatsu,J.Kotoku,M.Arimoto,N.Kawai,Y.Ishikawa,N.Kawabata
DOI: https://doi.org/10.1016/j.nima.2005.01.081
2006-02-17
Abstract:We have studied the performance of large area avalanche photodiodes (APDs) recently developed by Hamamatsu Photonics K.K, in high-resolution X-rays and Gamma-rays detections. We show that reach-through APD can be an excellent soft X-ray detector operating at room temperature or moderately cooled environment. We obtain the best energy resolution ever achieved with APDs, 6.4 % for 5.9 keV X-rays, and obtain the energy threshold as low as 0.5 keV measured at -20deg. Thanks to its fast timing response, signal carriers in the APD device are collected within a short time interval of 1.9 nsec (FWHM). This type of APDs can therefore be used as a low-energy, high-counting particle monitor onboard the forthcoming Pico-satellite Cute1.7. As a scintillation photon detector, reverse-type APDs have a good advantage of reducing the dark noise significantly. The best FWHM energy resolutions of 9.4+-0.3 % and 4.9+-0.2 % were obtained for 59.5 keV and 662 keV Gamma-rays, respectively, as measured with a CsI(Tl) crystal. Combination of APDs with various other scintillators (BGO, GSO, and YAP) also showed better results than that obtained with a photomultiplier tube (PMT). These results suggest that APD could be a promising device for replacing traditional PMT usage in some applications. In particular 2-dim APD array, which we present in this paper, will be a promising device for a wide-band X-ray and Gamma-ray imaging detector in future space research and nuclear medicine.
Astrophysics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: to evaluate and improve the performance of large - area avalanche photodiodes (APD) in high - resolution X - ray and gamma - ray detection, with the expectation of replacing traditional photomultiplier tubes (PMT) and being applied in future space research and nuclear medicine. ### Specific problems and solutions: 1. **Soft X - ray detection**: - **Problem**: Traditional detectors have problems such as insufficient sensitivity and not high enough energy resolution in the detection of low - energy X - rays (<20 keV). - **Solution**: The performance of reach - through APD at room temperature and in a moderately cooled environment was studied. The results show that this APD can achieve an energy resolution of 6.4% (for 5.9 keV X - rays), and the energy threshold is as low as 0.5 keV (measured at - 20°C). In addition, the collection time of signal carriers in the APD is only 1.9 nanoseconds (FWHM), making it suitable for high - count - rate particle monitoring. 2. **Gamma - ray detection**: - **Problem**: Traditional PMT has problems such as large dark noise and not high energy resolution in the detection of low - energy gamma - rays. - **Solution**: The performance of reverse - type APD when combined with different scintillators (such as CsI(Tl), BGO, GSO(Ce), YAP(Ce)) was studied. The results show that the energy resolution of APD in detecting 662 keV gamma - rays reaches 4.9 ± 0.2% (at room temperature), which is better than 5.9 ± 0.1% of traditional PMT. In addition, the lowest detectable energy of APD at low temperature (- 20°C) is as low as 1.1 keV, further improving the sensitivity. 3. **Imaging applications**: - **Problem**: The existing imaging devices have limited design flexibility and performance in space experiments and nuclear medicine. - **Solution**: A 32 - channel pixelated APD array was developed for future imaging devices. Preliminary results show that the energy threshold of each pixel is as low as 0.8 keV (at room temperature), and the crosstalk between adjacent pixels is less than 4%, providing new design options for future applications in nuclear medicine and space experiments. ### Conclusion: Through the above research, the paper shows the superior performance of APD in high - resolution X - ray and gamma - ray detection, especially in the low - energy region. These results indicate that APD is expected to replace traditional PMT in the future and play an important role in fields such as space research and nuclear medicine.