Standardizing Laser Speckle Orthogonal Contrast Imaging: Achieving Reproducible Measurements across Instruments

Xavier Orlik,Elise Colin,Aurélien Plyer
DOI: https://doi.org/10.3390/photonics11070585
IF: 2.536
2024-06-21
Photonics
Abstract:Using two independent speckle imaging systems based on the recently published LSOCI method operating in contact mode on the skin, we assess the reproducibility of in vivo measurements and conduct an inter-instrument comparison. To this aim, we propose a calibration method to handle each imaging system as a comprehensive unit, which includes the laser source, optics, and camera. Key to our method is the introduction of a new index that quantifies the departure of the temporal contrast observed in vivo from the spatial contrast scattered from a reference static element generating a circular Gaussian speckle field. Using such near-real-time calibration method, we demonstrate that the microcirculation images produced by 2 different instruments exhibit high accuracy and stability, with microcirculation activity values in excellent agreement, thereby paving the way for clinical applications.
optics
What problem does this paper attempt to address?
The paper aims to address several key issues in the clinical application of Laser Speckle Contrast Imaging (LSOCI) technology, including: 1. **Quantitative Metrics**: Each pixel should provide a quantitative microcirculation activity index, which is crucial for guiding treatment decisions. 2. **Stability during Repeated Acquisition**: When imaging the same area while the body is stationary, the technology must produce consistent and stable images and microcirculation activity values. 3. **Consistency between Instruments**: Results should be comparable between different imaging systems. 4. **Dynamic and Accurate Imaging**: The imaging system must have sufficient dynamic range, stability, and accuracy to distinguish different pathological states under in vivo conditions, despite challenges such as heartbeat cycles and inevitable movements. To achieve these goals, the authors developed two lightweight and compact LSOCI imaging systems and proposed a new calibration method (CVCM) to handle the overall characteristics of each imaging system. Through this method, the authors demonstrated that the microcirculation images produced by the two different instruments have high accuracy and stability, and the microcirculation activity values are highly consistent, paving the way for clinical applications. This is the first study to qualitatively and quantitatively compare two dynamic speckle imaging instruments in the same in vivo area.