Impact of 4D-Flow CMR Parameters on Functional Evaluation of Fontan Circulation

Lamia Ait Ali,Nicola Martini,Elisa Listo,Elisa Valenti,Julio Sotelo,Stefano Salvadori,Claudio Passino,Angelo Monteleone,Nicola Stagnaro,Gianluca Trocchio,Chiara Marrone,Francesca Raimondi,Giosuè Catapano,Pierluigi Festa
DOI: https://doi.org/10.1007/s00246-024-03446-4
2024-03-22
Pediatric Cardiology
Abstract:Abstract We sought to evaluate the potential clinical role of 4D-flow cardiac magnetic resonance (CMR)-derived energetics and flow parameters in a cohort of patients’ post-Fontan palliation. In patients with Fontan circulation who underwent 4D-Flow CMR, streamlines distribution was evaluated, as well a 4D-flow CMR-derived energetics parameters as kinetic energy (KE) and energy loss (EL) normalized by volume. EL/KE index as a marker of flow efficiency was also calculated. Cardiopulmonary exercise test (CPET) was also performed in a subgroup of patients. The population study included 55 patients (mean age 22 ± 11 years). The analysis of the streamlines revealed a preferential distribution of the right superior vena cava flow for the right pulmonary artery (62.5 ± 35.4%) and a mild preferential flow for the left pulmonary artery (52.3 ± 40.6%) of the inferior vena cave-pulmonary arteries (IVC-PA) conduit. Patients with heart failure (HF) presented lower IVC/PA-conduit flow (0.75 ± 0.5 vs 1.3 ± 0.5 l/min/m 2 , p = 0.004) and a higher mean flow-jet angle of the IVC-PA conduit (39.2 ± 22.8 vs 15.2 ± 8.9, p < 0.001) than the remaining patients. EL/KE index correlates inversely with VO 2 /kg/min: R : − 0.45, p = 0.01 peak, minute ventilation (VE) R : − 0.466, p < 0.01, maximal voluntary ventilation: R :0.44, p = 0.001 and positively with the physiological dead space to the tidal volume ratio (VD/VT) peak: R : 0.58, p < 0.01. From our data, lower blood flow in IVC/PA conduit and eccentric flow was associated with HF whereas higher EL/KE index was associated with reduced functional capacity and impaired lung function. Larger studies are needed to confirm our results and to further improve the prognostic role of the 4D-Flow CMR in this challenging population.
pediatrics,cardiac & cardiovascular systems
What problem does this paper attempt to address?
The paper aims to address the following issues: 1. **Evaluate the potential clinical role of energy and flow parameters derived from 4D Flow Cardiac Magnetic Resonance Imaging (4D-Flow CMR) in the Fontan circulation**: The study assessed the blood flow distribution in post-Fontan patients using 4D-Flow CMR technology and calculated parameters such as kinetic energy (KE) and energy loss (EL). 2. **Explore the impact of flow parameters on adverse outcomes in heart failure**: It was found that heart failure patients had lower blood flow in the IVC-PA conduit and a larger average flow jet angle. 3. **Investigate the association between energy parameters derived from 4D-Flow CMR and lung function and exercise capacity**: The study found that a higher EL/KE index was associated with reduced functional endurance (measured by peak VO2/kg/min) and impaired lung function. In summary, this study evaluated the hemodynamic characteristics of post-Fontan patients using 4D-Flow CMR technology and their relationship with clinical outcomes, providing new insights for the prognosis assessment of Fontan circulation patients.