A comparative study of boost dose delivery techniques in breast cancer radiotherapy optimising efficacy and minimising toxicity

Khalid El Ouardy,Mustapha Zerfaoui,Yassine Oulhouq,Karim Bahhous,Abdeslem Rrhioua,Dikra Bakari,Khalid El Ouardi
DOI: https://doi.org/10.1093/rpd/ncad328
2024-01-25
Radiation Protection Dosimetry
Abstract:Abstract The present study aims to compare three techniques for delivering a boost absorbed dose: conventional reduced tangential (3D), volumetric modulated arc therapy (VMAT) and fields forward-planned technique boost (3DF). The study included 15 postoperative breast cancer patients who received a boost absorbed dose following breast-conserving surgery. The conformity index and homogeneity index were used to evaluate treatment outcomes, along with the average absorbed dose received by organs at risk (OAR). All the calculated dosimetric plans are carried out using Monaco Treatment Planning System (TPS). VMAT offers superior conformity, dose homogeneity and target coverage, it is associated with higher absorbed doses to OAR such as the heart and lung. In contrast, the 3D and 3DF techniques exhibit advantages in reducing absorbed doses to critical structures, potentially minimising the risk of cardiac and pulmonary complications. Each technique has its advantages and disadvantages. The choice of technique should be individualised, taking into account patient-specific factors and treatment goals and involves a multidisciplinary approach.
environmental sciences,public, environmental & occupational health,radiology, nuclear medicine & medical imaging,nuclear science & technology
What problem does this paper attempt to address?