An improved design of high-signal-to-noise ratio spiral-coil EMAT for high-temperature defect detection

Yuxuan Zou Wenze Shi Chao Lu Bo Hu Fasheng Qiu Yuan Liu Key Laboratory of Nondestructive Testing,Ministry of Education,Nanchang Hangkong University,Nanchang,China
DOI: https://doi.org/10.1080/10589759.2024.2389953
2024-08-27
Nondestructive Testing And Evaluation
Abstract:The study introduces an enhanced concentric spiral-coil EMAT to tackle low signal-to-noise ratio (SNR) in high-temperature carbon steel forging defect detection. With a non-overlapping concentric coil design, simulations and experiments were conducted, utilizing a finite element model with circuit-field coupling to optimize parameters. Results show the improved EMAT enhances SNR by up to 20.96 dB compared to traditional designs. High-temperature tests demonstrate its capability to detect Ф5 mm holes at 650°C, with SNR increasing by 11.24 dB as temperature rises from 100°C to 500°C, validating the optimization method's effectiveness.
materials science, characterization & testing
What problem does this paper attempt to address?