Feasibility Study for Monitoring an Ultrasonic System Using Structurally Integrated Piezoceramics

Jonas M. Werner,Tim Krüger,Welf-Guntram Drossel
DOI: https://doi.org/10.3390/s24031036
IF: 3.9
2024-02-06
Sensors
Abstract:This paper presents a new approach to monitoring ultrasonic systems using structurally integrated piezoceramics. These are integrated into the sonotrode at different points and with different orientations. The procedure for integrating the piezoceramics into the sonotrode and their performance is experimentally investigated. We examine whether the measured signal can be used to determine the optimal operating frequency of the ultrasonic system, if integrating several piezoceramics enables discernment of the current vibration shape, and if the piezoceramics can withstand the high strains caused by the vibrations in a frequency range of approximately 20–25 kHz. The signals from the piezoceramic sensors are compared to the real-time displacement at different points of the sonotrode using a 3D laser scanning vibrometer. To evaluate the performance of the sensors, different kinds of excitation of the ultrasonic system are chosen.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The paper primarily explores the feasibility of using structurally integrated piezoceramics (SIP) to monitor ultrasonic systems. Specifically, the research objectives include: 1. **Determining the optimal operating frequency**: Assessing whether the optimal operating frequency of the ultrasonic system can be identified by measuring signals. 2. **Identifying vibration modes**: Integrating multiple piezoceramic sensors at different positions and directions on the sonotrode to determine if the current vibration modes can be distinguished. 3. **Durability testing**: Evaluating whether the piezoceramic sensors can withstand the high strain induced by ultrasonic vibrations, particularly in the frequency range of approximately 20 to 25 kHz. To achieve these objectives, the researchers conducted experiments that included integrating piezoceramic sensors into the sonotrode and comparing the signals from these sensors with actual displacement data obtained using a 3D laser scanning vibrometer. Additionally, different ultrasonic system excitation methods were selected to evaluate the performance of the sensors. This study aims to improve the control mechanisms of ultrasonic systems, enabling them to operate more precisely and efficiently in industrial applications.