Ultracompact X-Ray Binaries with Neon-Rich Degenerate Donors

Adrienne M. Juett,Dimitrios Psaltis,Deepto Chakrabarty
DOI: https://doi.org/10.1086/324225
2001-08-09
Abstract:There are three low-mass X-ray binaries (4U 0614+091, 2S 0918-549, and 4U 1543-624) for which broad line emission near 0.7 keV was previously reported. A recent high-resolution observation of 4U 0614+091 with the Chandra/LETGS found evidence for an unusually high Ne/O abundance ratio along the line of sight but failed to detect the previously reported 0.7 keV feature. We have made a search of archival ASCA spectra and identified a fourth source with the 0.7 keV feature, the 20-min ultracompact binary 4U 1850-087. In all four of these sources, the 0.7 keV residual is eliminated from the ASCA spectra by allowing excess photoelectric absorption due to a non-solar relative abundance of neon, just as in the LETGS spectrum of 4U 0614+091. The optical properties of these systems suggest that all four are ultracompact (P_orb<80 min) binaries. We propose that there is excess neon local to each of these sources, as also found in the ultracompact binary pulsar 4U 1626-67. We suggest that the mass donor in these systems is a low-mass, neon-rich degenerate dwarf and that the binaries are all ultracompact.
Astrophysics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to explain the origin of the 0.7 keV characteristic emission line observed in some low - mass X - ray binaries (LMXBs). Specifically, the researchers found that there are four ultra - compact X - ray binary systems (4U 0614+091, 2S 0918−549, 4U 1543−624 and the newly identified 4U 1850−087) showing a prominent 0.7 keV feature in their spectra. ### Main problems: 1. **Source of the 0.7 keV feature**: Earlier studies reported the existence of a broad emission line feature at approximately 0.7 keV in these systems. However, recent high - resolution observations using the Chandra X - ray Observatory failed to detect this feature, but instead found an abnormally high Ne/O abundance ratio. This has raised doubts about the authenticity of the 0.7 keV feature. 2. **Cause of abundance anomaly**: The researchers proposed that this feature may be due to excessive neon element absorption along the line of sight. In particular, in ultra - compact binary systems, there may be neon - rich degenerate dwarfs as matter donors. ### Solutions: To verify this hypothesis, the authors re - analyzed the archived data of the ASCA satellite and allowed the relative abundances of oxygen and neon in the model to vary. The results showed that: - When taking into account excessive neon absorption, the spectra of all four systems can be well - fitted without introducing the 0.7 keV emission line. - This result is consistent with the Chandra/LETGS observations of 4U 0614+091, which also found a stronger - than - expected neon absorption edge but did not detect an emission line. ### Conclusions: The researchers believe that the common feature of these systems is that they are all ultra - compact binaries, with low - mass and neon - rich degenerate dwarfs as matter donors. In addition, there may also be neutral materials around these systems, which may be ejected from the accretion disk. In this way, this paper has solved the problems regarding the authenticity of the 0.7 keV feature and its physical origin, and proposed a new model to explain these observational results.