Modulation and Control Strategy of 3CH4 Combined Current Source Grid-Connected Inverter

Pengcheng Li,Liming Huo,Yingjun Guo,Guoqing An,Xiaoqiang Guo,Zheng Li,Hexu Sun
DOI: https://doi.org/10.3390/en15124219
IF: 3.2
2022-06-09
Energies
Abstract:In this article, a topology based on the single-phase full-bridge is proposed to decouple control of phase current in current source grid-connected inverters. The DC side of this current source inverter topology can operate with a common DC bus or independently, and the AC side can be independently integrated into the three-phase grid or operate in parallel. This topology needs only a simple control logic and phase information to achieve 3-phase current decoupling control, which can accommodate a wide range of voltage fluctuations. Then, dual-carrier driving and hybrid damping correction strategies are designed to achieve flexible combinatorial operation and eliminate the common-mode voltage. Meanwhile, the method is simple and easy to implement in practice. The effectiveness of the proposed algorithm is validated with experiments.
energy & fuels
What problem does this paper attempt to address?