Measuring and Controlling the Energy Spread in CEBAF

G. A. Krafft,J.-C. Denard,R. W. Dickson,R. Kazimi,V. A. Lebedev,M. G. Tiefenback
DOI: https://doi.org/10.48550/arXiv.physics/0009087
2000-09-28
Abstract:As compared to electron storage rings, one advantage of recirculating linear accelerators is that the beam properties at target are no longer dominated by the equilibrium between quantum radiative diffusion and radiation damping because new beam is continually injected into the accelerator. This allows the energy spread from a CEBAF-type machine to be relatively small; the measured energy spread from CEBAF at 4 GeV is less than 100 parts per million accumulated over times of order several days. In this paper, the various subsystems contributing to the energy spread of a CEBAF-type accelerator are reviewed, as well as the machine diagnostics and controls that are used in CEBAF to ensure that a small energy spread is provided during routine running. Examples of relevant developments are (1) stable short bunches emerging from the injector, (2) precision timing and phasing of the linacs with respect to the centroid of the beam bunches on all passes, (3) implementing 2 kHz sampling rate feedback systems for final energy stabilization, and (4) continuous beam energy spread monitoring with optical transition radiation devices. We present measurement results showing that small energy spreads are achieved over extended periods.
Accelerator Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to measure and control the energy spread in CEBAF (Continuous Electron Beam Accelerator Facility). Specifically, the authors explore how to ensure a small energy spread is maintained during long - term operation, which is crucial for high - precision nuclear physics experiments. ### Main problem decomposition: 1. **Sources of energy spread**: - Energy spread of a single pulse: including energy spread at injection, phase spread, synchrotron radiation effects, etc. - Energy fluctuations: Caused by factors such as phase and amplitude fluctuations of RF cavities, main oscillator noise, magnetic field fluctuations, etc. 2. **Solutions**: - **Optimizing injector design**: Ensure that the electron beam emerging from the injector has a small initial energy spread and good longitudinal phase - space matching. - **Precise phase control**: Minimize the phase error in each acceleration section through feedback systems and path length adjustments. - **Fast feedback system**: Used to correct energy fluctuations at 60Hz and its harmonic frequencies in real - time to ensure energy stability. - **Diagnostic devices**: Use devices such as slow - wire scanners and optical transition radiation (OTR) monitors to continuously monitor and record beam conditions. ### Key technical means: - **Injector optimization**: Through methods such as phase transfer function measurement, ensure that the beam output from the injector has an ideal longitudinal phase - space distribution. - **Path length and M56 measurement**: Use longitudinal pickup cavities and phase detectors to accurately measure the time of arrival of each path to determine the M56 value. - **Main oscillator modulation system**: Continuously monitor and adjust the RF phase to ensure that all acceleration sections are close to the optimal phase. - **Fast feedback system**: Adopt a digital feedback system to correct beam position and energy fluctuations in real - time. - **Energy spread diagnosis**: Use slow - wire scanners and OTR monitors to provide high - resolution beam profiles and ensure continuous monitoring of energy spread. ### Application background: CEBAF is a continuous electron beam accelerator for nuclear physics research, and its goal is to provide high - quality, low - energy - spread electron beams for experiments. To meet this requirement, it is necessary to ensure that the energy spread remains within a very small range (such as \( < 10^{-4} \)) throughout the operation, which requires fine control and continuous monitoring of all subsystems of the accelerator. ### Summary: This paper describes in detail the methods for measuring and controlling energy spread in the CEBAF accelerator, showing how to ensure that the energy spread remains within a very small range during long - term operation through optimizing injector design, precise phase control, fast feedback systems, and advanced diagnostic devices. These technical means not only improve the quality of experimental data but also lay the foundation for future high - precision nuclear physics experiments.