Experimental Study of Tuning Method on a Model Alvarez DTL Cavity for CPHS Project
Lei Yu,Xialing Guan,Ruo Tang,Xuewu Wang,Qingzi Xing,Shuxin Zheng
DOI: https://doi.org/10.18429/jacow-linac2018-thpo034
2019-01-01
Abstract:This article is devoted to the experimental study of tuning method for an Alvarez-type drift tube linac (DTL) of the Compact Pulse Hadron Source (CPHS) project at Tsinghua University. The biperiodic structure based on the post couplers are introduced to overcome the instability of the Alvarez DTL tank which is used to operate in 0 (or 2π) mode. The experimental method and results are presented, and the tuning scheme for the formal CPHS DTL is summarized from the tuning experiment. INTRODUCTION The effective shunt impedance of the Alvarez-type DTL is typically high when it operates in a typical 0 (or 2π) mode with the group velocity of 0. But the structure is very susceptible to perturbation such as the beam loading, mechanical and installation error, because of the narrow space near the adjacent modes on the TM dispersion curve. The post couplers, which are the resonant-coupling elements constitutionally, are mounted on the wall of the DTL cavity oppositely and alternatively to introduce a new PCs (post couplers) dispersion curve. When the stopband between the two passbands of the dispersion curves disappears by adjusting the slugging length of the post couplers, the lowest frequency of the TM passband will be moved to the π/2 mode point of the new dispersion curve. Therefore the new stable biperiodic structure of the DTL will be achieved [1]. To verify the tuning method, one model cavity has been machined and the turning experiment is carried out based on the cavity. The cavity is designed and manufactured for verifying the mechanical design and undertaking some low-power experiment. The model cavity consists of ten full drift tubes, two half drift tubes mounted on the end flanges, three post couplers and two tuners [2]. The end of the post couplers is designed to be eccentric to facilitate the tuning of the local field distribution by rotating the post. TUNING EXPERIMENTAL CONFIGURATION On the experimental stand as shown in Fig. 1, the measurement based on the bead-pull method is executed. According to the perturbation theory, when the bead is pulled into the field between the two adjacent drift tubes, the resonant frequency changes. Then the corresponding phase shift can be detected by a vector network analyzer (VNA) and the electric field along the beam-axis can be deduced [3]. Figure: 1 Tuning experimental stand. A stepping motor is adopted to pull a fine nylon line on which the small perturbation bead is fixed. The size of the bead shall be rather appropriate, so that the responsive signal caused by the bead is big enough compared with the background noise and at the same time within the linear range of the phase around the resonant frequency. It depends on the Q factor of the cavity. The Q factor of this model cavity is measured as 17796 which is about 44% of the designed value. It is because that the surfaces of the interior copper-plated cavity wall and the aluminous end flanges are oxidic. With the value of the Q factor, the radius of the bead is determined as 0.7 mm by estimation. To ensure the accuracy of the measurement, the peak field is employed to represent the field distribution instead of the integral one due to its further advantages [4]. Before the measurement, the reproducibility is checked. The reproducibility Rij is defined by Eq. (1).