Absolute calibration of the ratio of Xe/O two-photon absorption cross-sections for O-TALIF applications

Zhan Shu,Nikolay A Popov,Svetlana M Starikovskaia
DOI: https://doi.org/10.1088/1361-6595/ad270f
2024-02-09
Plasma Sources Science and Technology
Abstract:The paper presents a calibration of the ratio of two-photon absorption cross sections, , necessary for the absolute O-atom density measurements by two-photon absorption laser-induced fluorescence (TALIF) technique. To calibrate the ratio of the cross-sections, a special discharge with 100\% dissociation of molecular oxygen, and so with a known "reference" density of O-atom [O] =2 [O ] was suggested. This is a nanosecond capillary discharge in N : O mixtures with a few percent of oxygen at a reduced electric field of a few hundred of Td and specific deposited energy of about 1 eV/molecule. Voltage at the electrodes, electrical current in the plasma, longitudinal electric field and energy delivered to the gas were measured with 0.2~ns synchronisation. Additionally, radial distribution of emission of excited nitrogen molecules and gas temperature in the discharge and afterglow were obtained experimentally. Detailed 1D kinetic modeling was suggested to confirm complete O dissociation and to analyse the main reactions. By comparing the data measured by TALIF technique with the ``reference'' density of oxygen atoms [O] , the ratio of the two-photon absorption cross-sections was determined.
physics, fluids & plasmas