Peptide Nucleic Acid-Functionalized Nanochannel Biosensor for the Highly Sensitive Detection of Tumor Exosomal MicroRNA

Ping-Ping Xiao,Qiang-Qiang Wan,Tangbin Liao,Ji-Yuan Tu,Guo-Jun Zhang,Zhong-Yue Sun
DOI: https://doi.org/10.1021/acs.analchem.1c01898
IF: 7.4
2021-07-30
Analytical Chemistry
Abstract:Compared with free miRNAs in blood, miRNAs in exosomes have higher abundance and stability. Therefore, miRNAs in exosomes can be regarded as an ideal tumor marker for early cancer diagnosis. Here, a peptide nucleic acid (PNA)-functionalized nanochannel biosensor for the ultrasensitive and specific detection of tumor exosomal miRNAs is proposed. After PNA was covalently bound to the inner surface of the nanochannels, the detection of tumor exosomal miRNAs was achieved by the charge changes on the surface of nanochannels before and after hybridization (PNA–miRNA). Due to the neutral characteristics of PNA, the efficiency of PNA–miRNA hybridization was improved by significantly reducing the background signal. This biosensor could not only specifically distinguish target miRNA-10b from single-base mismatched miRNA but also achieve a detection limit as low as 75 aM. Moreover, the biosensor was further used to detect exosomal miRNA-10b derived from pancreatic cancer cells and normal pancreatic cells. The results indicate that this biosensor could effectively distinguish pancreatic cancer tumor-derived exosomes from the normal control group, and the detection results show good consistency with those of the quantitative reverse-transcription polymerase chain reaction method. In addition, the biosensor was used to detect exosomal miRNA-10b in clinical plasma samples, and it was found that the content of exosomal miRNA-10b in cancer patients was generally higher than that of healthy individuals, proving that the method is expected to be applied for the early diagnosis of cancer.The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acs.analchem.1c01898.Characterization of exosomes, qRT-PCR protocol, PNA probe sequence and miRNA sequences, comparison of different methods for exosomal miRNA detection, FE-SEM images of conical PET nanochannels, wettability of nanochannel before and after PNA modification, optimizations of experimental conditions, stability of the PNA-functionalized nanochannel biosensor, and TEM characterizations and NTA results of H6C7 exosomes (PDF)This article has not yet been cited by other publications.
chemistry, analytical
What problem does this paper attempt to address?