Detecting pipeline leakage using active distributed temperature Sensing: Theoretical modeling and experimental verification

Hao-Jie Li,Hong-Hu Zhu,Dao-Yuan Tan,Bin Shi,Jian-Hua Yin
DOI: https://doi.org/10.1016/j.tust.2023.105065
IF: 6.9
2023-03-04
Tunnelling and Underground Space Technology
Abstract:This paper presents a feasibility study on leak detection of buried pipelines using the active distributed temperature sensing (ADTS) method. The proposed solution involves the use of actively heated fiber optic (AHFO) cables arranged parallel to the pipelines, allowing for changes in the thermal properties of the surrounding soil to be captured and correlated with leakage accidents. This problem was modeled as an infinite cylindrical or linear heat source buried in porous media with seepage flowing inside. AHFO sensors were designed to verify the proposed method through scale-reduced model tests. The fiber optic temperature sensing technology based on optical frequency domain reflectometry (OFDR) was used to continuously monitor temperature profiles. The test results demonstrate that the ADTS solution has greatly improved the accuracy of passive temperature sensing methods. The feasibility of the solution was evaluated regarding different levels of leakage estimation, namely, identification, location, and quantification. This paper presents the first attempt to monitor the infiltration process associated with pipeline leaks using the AHFO-OFDR technique, which is a reliable method for structural health monitoring of underground pipelines.
construction & building technology,engineering, civil
What problem does this paper attempt to address?