Screening Indicators Analysis for the Echelon Utilization of Lithium-ion Batteries

Hao Su,Jichang Peng,Mingqiang Lin,Xi Chen,Ji Wu,Jinhao Meng
DOI: https://doi.org/10.1109/ICSC57768.2022.9993932
2022-11-23
Abstract:Owing to the inconsistent decay among cells during their applications, the battery uniformity is low, which seriously restricts the economy and efficiency of the cascade utilization of large-scale retired lithium batteries. Moreover, due to the complex chemical reaction inside the battery, the degradation process cannot be accurately described. It is particularly critical to select appropriate health indicators (HI) for screening and evaluating the value of the battery for echelon utilization. Given the above problems, this paper uses the measurement of a battery tester to extract suitable HI subsets from the charging curve, IC curve, and other curves, and uses the Pearson correlation coefficient to analyze the correlations for subsets of HI. The effective HIs for screening the secondary use of the battery are suggested. Experimental results prove the good correlation characteristics of the recommended HI with battery capacity, which can be further used to improve the accuracy and efficiency of battery screening.
Computer Science,Materials Science,Engineering