In Situ Gastric pH Imaging with Hydrogel Capsule Isolated Paramagnetic Metallo-albumin Complexes

Yiting Xu,Yanxia Yang,Zhiwei Yin,Xinqi Cai,Xin Xia,Michael J. Donovan,Long Chen,Zhuo Chen,Weihong Tan
DOI: https://doi.org/10.1021/acs.analchem.1c00538
IF: 7.4
2021-03-31
Analytical Chemistry
Abstract:Abnormal gastric pH (pH &gt; 3) has instructive significance for early diagnosis of various diseases, including cancer. However, for low patient compliance, limited penetration depth, high dependence on physiological function or unsafety issue, <i>in situ</i> noninvasive monitoring gastric pH is challenged. Herein, we developed a hydrogel capsule isolated human serum albumin-manganese complex (HSA-Mn) for <i>in situ</i> magnetic resonance imaging (MRI) gastric pH monitoring for the first time. In this strategy, the rotation motion restriction of Mn<sup>2+</sup> after binding to HSA significantly increased the <i>R</i><sub>1</sub> (longitudinal relaxation rate) signal, and its high correlation with protonation imparted the HSA-Mn system sensitive responsiveness to varying pH (<i>R</i><sub>1</sub>(pH 7)/<i>R</i><sub>1</sub>(pH 1) = 8.2). Moreover, a screw jointed hydrogel capsule with signal confinement and internal standard abilities was designed. Such a nanoporous hydrogel capsule with size selectivity to surrounding molecules enabled a stable and sensitive response to different pH simulated gastric fluid within 0.5 h. In addition, with the unique structural outline and stable MRI characteristics, the capsule could also work as an internal standard, which facilitates the collection of signals and trace of the capsule <i>in vivo</i>. Through validating in a rabbit model, the precise abnormal gastric pH recognition capacity of the HSA-Mn hydrogel capsule was amply confirmed. Hence, the hydrogel capsule isolated HSA-Mn system strategy with great biocompatibility could be expected to be a potent tool for <i>in situ</i> anti-disturbance MRI of gastric pH in future clinical application.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acs.analchem.1c00538?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acs.analchem.1c00538</a>.Chemical and reagents, experimental equipment and details, and more MRI pictures <i>in vivo</i> (<a class="ext-link" href="/doi/suppl/10.1021/acs.analchem.1c00538/suppl_file/ac1c00538_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
chemistry, analytical
What problem does this paper attempt to address?