Quantification of myocardial scar of different etiology using dark- and bright-blood late gadolinium enhancement cardiovascular magnetic resonance

Lamis Jada,Robert J. Holtackers,Bibi Martens,Hedwig M. J. M. Nies,Caroline M. Van De Heyning,Rene M. Botnar,Joachim E. Wildberger,Tevfik F. Ismail,Reza Razavi,Amedeo Chiribiri
DOI: https://doi.org/10.1038/s41598-024-52058-8
IF: 4.6
2024-03-07
Scientific Reports
Abstract:Dark-blood late gadolinium enhancement (LGE) has been shown to improve the visualization and quantification of areas of ischemic scar compared to standard bright-blood LGE. Recently, the performance of various semi-automated quantification methods has been evaluated for the assessment of infarct size using both dark-blood LGE and conventional bright-blood LGE with histopathology as a reference standard. However, the impact of this sequence on different quantification strategies in vivo remains uncertain. In this study, various semi-automated scar quantification methods were evaluated for a range of different ischemic and non-ischemic pathologies encountered in clinical practice. A total of 62 patients referred for clinical cardiovascular magnetic resonance (CMR) were retrospectively included. All patients had a confirmed diagnosis of either ischemic heart disease (IHD; n = 21), dilated/non-ischemic cardiomyopathy (NICM; n = 21), or hypertrophic cardiomyopathy (HCM; n = 20) and underwent CMR on a 1.5 T scanner including both bright- and dark-blood LGE using a standard PSIR sequence. Both methods used identical sequence settings as per clinical protocol, apart from the inversion time parameter, which was set differently. All short-axis LGE images with scar were manually segmented for epicardial and endocardial borders. The extent of LGE was then measured visually by manual signal thresholding, and semi-automatically by signal thresholding using the standard deviation (SD) and the full width at half maximum (FWHM) methods. For all quantification methods in the IHD group, except the 6 SD method, dark-blood LGE detected significantly more enhancement compared to bright-blood LGE ( p < 0.05 for all methods). For both bright-blood and dark-blood LGE, the 6 SD method correlated best with manual thresholding (16.9% vs. 17.1% and 20.1% vs. 20.4%, respectively). For the NICM group, no significant differences between LGE methods were found. For bright-blood LGE, the 5 SD method agreed best with manual thresholding (9.3% vs. 11.0%), while for dark-blood LGE the 4 SD method agreed best (12.6% vs. 11.5%). Similarly, for the HCM group no significant differences between LGE methods were found. For bright-blood LGE, the 6 SD method agreed best with manual thresholding (10.9% vs. 12.2%), while for dark-blood LGE the 5 SD method agreed best (13.2% vs. 11.5%). Semi-automated LGE quantification using dark-blood LGE images is feasible in both patients with ischemic and non-ischemic scar patterns. Given the advantage in detecting scar in patients with ischemic heart disease and no disadvantage in patients with non-ischemic scar, dark-blood LGE can be readily and widely adopted into clinical practice without compromising on quantification.
multidisciplinary sciences
What problem does this paper attempt to address?
The paper primarily explores the methods and effectiveness of using dark-blood and bright-blood Late Gadolinium Enhancement (LGE) cardiovascular magnetic resonance imaging techniques for myocardial scar quantification in patients with different heart diseases. ### Research Background and Objectives The paper points out that although the traditional bright-blood LGE cardiovascular magnetic resonance imaging technique is widely used to identify myocardial scar areas, it may underestimate the extent of scarring in certain cases (such as subendocardial scars in ischemic cardiomyopathy). To overcome this limitation, the researchers proposed a method to obtain dark-blood LGE images without the need for additional RF pulse preparation. This method improves the contrast of ischemic scars relative to the blood pool and better detects and visualizes these scars. ### Main Research Content - **Study Subjects**: The study included 62 patients diagnosed with Ischemic Heart Disease (IHD), Non-Ischemic Cardiomyopathy (NICM), or Hypertrophic Cardiomyopathy (HCM). - **Research Methods**: All patients underwent 1.5 Tesla magnetic resonance scans, including both bright-blood and dark-blood LGE imaging. The study compared several different scar quantification methods (including manual threshold segmentation, standard deviation [SD] threshold method, and full width at half maximum [FWHM] method) and evaluated the effectiveness of these methods in different heart disease groups. - **Main Findings**: - In the IHD patient group, the dark-blood LGE technique detected significantly more scars than the bright-blood LGE technique (except when using the 6 SD method). - For the NICM and HCM patient groups, the extent of scars detected by both LGE techniques was similar. - Semi-automatic quantification methods (SD and FWHM methods) can be applied to dark-blood LGE images just as they are applied to bright-blood LGE images. ### Conclusion The study confirms that the dark-blood LGE technique can more accurately detect myocardial scars in patients with ischemic heart disease and that various scar quantification methods can also be effectively applied to patients with non-ischemic heart diseases (such as NICM and HCM). This indicates that the dark-blood LGE technique is suitable not only for clinical practice in patients with ischemic heart disease but also for scar detection and quantification in non-ischemic heart diseases.