Heart Rate Variability Monitoring Based on Doppler Radar Using Deep Learning

Sha Yuan,Shaocan Fan,Zhenmiao Deng,Pingping Pan
DOI: https://doi.org/10.3390/s24072026
IF: 3.9
2024-03-23
Sensors
Abstract:The potential of microwave Doppler radar in non-contact vital sign detection is significant; however, prevailing radar-based heart rate (HR) and heart rate variability (HRV) monitoring technologies often necessitate data lengths surpassing 10 s, leading to increased detection latency and inaccurate HRV estimates. To address this problem, this paper introduces a novel network integrating a frequency representation module and a residual in residual module for the precise estimation and tracking of HR from concise time series, followed by HRV monitoring. The network adeptly transforms radar signals from the time domain to the frequency domain, yielding high-resolution spectrum representation within specified frequency intervals. This significantly reduces latency and improves HRV estimation accuracy by using data that are only 4 s in length. This study uses simulation data, Frequency-Modulated Continuous-Wave radar-measured data, and Continuous-Wave radar data to validate the model. Experimental results show that despite the shortened data length, the average heart rate measurement accuracy of the algorithm remains above 95% with no loss of estimation accuracy. This study contributes an efficient heart rate variability estimation algorithm to the domain of non-contact vital sign detection, offering significant practical application value.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The paper aims to address the following issues: Current Doppler radar-based heart rate (HR) and heart rate variability (HRV) monitoring technologies typically require data lengths exceeding 10 seconds, which leads to increased detection delays and insufficient accuracy in HRV estimation. To solve this problem, this paper proposes a new network architecture that combines a frequency representation module and a Residual in Residual module, designed to accurately estimate and track heart rate from short time series and perform HRV monitoring. Specifically, the network transforms radar signals from the time domain to the frequency domain, generating high-resolution spectral representations within specific frequency ranges. This significantly reduces delay and improves HRV estimation accuracy using only 4 seconds of data. The study validates the model's effectiveness using simulation data, Frequency Modulated Continuous Wave (FMCW) radar measurement data, and Continuous Wave (CW) radar data. Experimental results show that despite the shortened data length, the algorithm's average heart rate measurement accuracy remains above 95%, with no loss in estimation precision. This research contributes an efficient heart rate variability estimation algorithm to the field of non-contact vital sign detection, with significant practical application value.