Enhanced Hemocompatibility of a Direct Chemical Vapor Deposition-Derived Graphene Film
Xuejuan Meng,Yi Cheng,Puxin Wang,Ke Chen,Zhaolong Chen,Xiaojun Liu,Xuefeng Fu,Kun Wang,Kaihui Liu,Zhongfan Liu,Xiaojie Duan
DOI: https://doi.org/10.1021/acsami.0c19790
2021-01-21
Abstract:A wide range of biomedical devices are being used to treat cardiovascular diseases, and thus they routinely come into contact with blood. Insufficient hemocompatibility has been found to impair the functionality and safety of these devices through the activation of blood coagulation and the immune system. Numerous attempts have been made to develop surface modification approaches of the cardiovascular devices to improve their hemocompatibility. However, there are still no ideal "blood-friendly" coating materials, which possess the desired hemocompatibility, tissue compatibility, and mechanical properties. As a novel multifunctional material, graphene has been proposed for a wide range of biomedical applications. The chemical inertness, atomic smoothness, and high durability make graphene an ideal candidate as a surface coating material for implantable devices. Here, we evaluated the hemocompatibility of a graphene film prepared on quartz glasses (Gra-glasses) from a direct chemical vapor deposition process. We found that the graphene coating, which is free of transfer-mediating polymer contamination, significantly suppressed platelet adhesion and activation, prolonged coagulation time, and reduced <i>ex vivo</i> thrombosis formation. We attribute the excellent antithrombogenic properties of the Gra-glasses to the low surface roughness, low surface energy (especially the low polar component of the surface energy), and the negative surface charge of the graphene film. Given these excellent hemocompatible properties, along with its chemical inertness, high durability, and molecular impermeability, a graphene film holds great promise as an antithrombogenic coating for next-generation cardiovascular devices.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acsami.0c19790?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acsami.0c19790</a>.Typical Raman spectra of graphene on Gra-glass1, Gra-glass2, Gra-glass3, and Gra-tube surfaces; typical SEM images of Gra-glass1, Gra-glass2, and Gra-glass3 surfaces; the weight of thrombus formed on Gra-tube and bare tube samples placed at different positions; the surface of various samples observed by atomic force microscopy or an optical profiler; the contact angle between different liquid and various sample surfaces; linear fitting according to the formula 5 for different samples; the surface energy of different liquids; and hemocompatibility of graphene and its analogues from the literature (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c19790/suppl_file/am0c19790_si_001.pdf">PDF</a>)Bare glass tubes were completely blocked by the thrombus, whereas the Gra-glass tubes retained excellent patency after <i>ex vivo</i> thrombogenicity experiments for 60 min (Video S1) (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c19790/suppl_file/am0c19790_si_002.mp4">MP4</a>)This article has not yet been cited by other publications.
materials science, multidisciplinary,nanoscience & nanotechnology