The Distribution of Seismic Shearing Force in Frame- Shear Wall Structure

L. Si-jia
Abstract:The provisions about the distribution of seismic shearing force of frame shear wall structures in《Code for seismic design of buildings》and《Technical specification for concrete structures of tall building》in our country are based on domestic and foreign design experience,however the lateral stiffness ratio of frame and shear wall are not including in their consideration. For solving this problem, this paper states that the seismic response on several buildings, which have 8-frame-sheared wall structure,with stiffness characteristic values arranging from 1.0 to 4.5,by the application of static elastic-plastic analysis method(Pushover)and dynamic time-history method. This study summarizes that different stiffness value of storey shearing force is distributed on frame-shear wall structure under different frequency of earthquake. The influence of shear wall stiffness degradation on the distribution of storey shearing force is also mentioned in this article. The formula about a frame structural storey shearing force distribution is supported for further designs and studies.
Engineering,Environmental Science