P225. Adherence of mycobacterium tuberculosis on material surface of nano-hydroxyapatite/polyamide 66 composite and long-term results of clinic application to spinal tuberculosis

Qiujiang Li,Yueming Song
DOI: https://doi.org/10.1016/j.spinee.2024.06.348
IF: 4.297
2024-08-20
The Spine Journal
Abstract:BACKGROUND CONTEXT Exploring artificial materials for anterior column reconstruction following the removal of thoracolumbar tuberculosis focus is of great value. The low possibility of adhesion and biofilm formation of Mycobacterium tuberculosis (M.tuberculosis) on nano-hydroxyapatite/polyamide 66(n-HA/PA66) provides a foundation for successful internal fixation in spinal tuberculosis. However, evidence on both clinical and microbiological perspectives is still lacking. PURPOSE To evaluate the adherence ability of M.tuberculosis in n-HA/PA66 and the long-term results of n-HA/PA66 in clinic application to spinal tuberculosis. STUDY DESIGN/SETTING Not Applicable PATIENT SAMPLE Not Applicable OUTCOME MEASURES Not Applicable METHODS M.tuberculosis were cultured with 4 types of metal segments, smooth or rough surfaced n-HA/PA66, and titanium, respectively. The characteristics of adhesion and biofilm formation were observed under scanning electron microscope. There were twenty patients who underwent the debridement and strut graft with n-HA/PA66 cage combined with anterior instrumentations between June 2009 and January 2011 included in this study. There were 9 male and 11 female patients with the mean age of 39.81±7.34 years. The level of surgery was T3-T10 in 8 cases, T11-L2 in 10 cases, and L3-L4 in 2 cases. The AIS grade was C in 4, D in 11, and E in 5 patient. Patients with cold abscess was found in 15 cases, intraspinal involvement in 16 cases, sinus in 2 cases. The neurological functions of patients with spinal fracture were evaluated by ASIA grading. Visual analog scale (VAS) and Japanese Orthopaedic Association (JOA) score were used to evaluate the improvement of the clinical symptoms. The X-ray and three-dimensional CT were followed up in all these patients to observe bony fusion, cage subsidence and translocation. RESULTS The average value of colony forming units (CFUs) of M. tuberculosis in smooth or rough surfaced n-HA/PA66 were significantly lower than those in titanium (P<0.01). M. tuberculosis biofilms had not formed at the n-HA/PA66. All patients successfully completed one-stage lesion debridement, the mean operating time was 187.4±44.3 min, intraoperative blood loss was 382.61±89.26 ml. Twenty cases of patients with postoperative neurological damage did not worsen, including 1 case of neurological function improved from preoperative grade C to postoperative grade D, but two days later the neurological function decreased to grade C due to paravertebral effusion. Finally, the last follow-up neurological function recovered to grade D after incision and drainage. The VAS score was relieved from 7.11±1.75 points before operation to 2.42±0.61 points after operation and 1.38±0.42 points at the last follow-up. The JOA score was increased from 6.7±3.1 points before operation to 15.7±4.5 points after operation and 23.4±3.3 points at the last follow-up. All cases showed no screw loosening, implant displacement or breakage. The preoperative kyphosis Cobb angle range was 14° to 82°(32.41°±11.45°), which decreased to 2° to 47° (mean of 19.55°±10.21°) postoperatively. However, at the final follow-up, the mean kyphosis Cobb angle slightly increased to 3° to 57° (mean of 23.44°±9.15°). The mean correction of kyphosis Cobb angle was 10° to 36° (mean of 14.07°±4.01°), while the mean loss of kyphosis Cobb angle was 1° to 11° (mean of 4.02°±0.77°). Bony fusion was achieved in 12 patients (60%) at 6 months, in 19 patients (95%) at 1 year, and in all patients at 2 years. However, during the follow-up period, cage subsidence was common in this group of cases, occurring in 11 cases (55%). The subsidence mainly occurred within 6 months after operation, ranging from 0 to 6 mm (mean of 2.45±0.81 mm). CONCLUSIONS The use of n-HA/PA66 has been proven effective in reducing the attachment of M. tuberculosis to the implant surface. Additionally, long-term clinical follow-up results have confirmed that this material is an ideal option for anterior column reconstruction following the removal of thoracolumbar tuberculosis focus. FDA Device/Drug Status This abstract does not discuss or include any applicable devices or drugs.
clinical neurology,orthopedics
What problem does this paper attempt to address?