Simultaneous Detection of Exosomal microRNAs Isolated from Cancer Cells Using Surface Acoustic Wave Sensor Array with High Sensitivity and Reproducibility

Su Bin Han,Soo Suk Lee
DOI: https://doi.org/10.3390/mi15020249
IF: 3.4
2024-02-08
Micromachines
Abstract:We present a surface acoustic wave (SAW) sensor array for microRNA (miRNA) detection that utilizes photocatalytic silver staining on titanium dioxide (TiO2) nanoparticles as a signal enhancement technique for high sensitivity with an internal reference sensor for high reproducibility. A sandwich hybridization was performed on working sensors of the SAW sensor array that could simultaneously capture and detect three miRNAs (miRNA-21, miRNA-106b, and miRNA-155) known to be upregulated in cancer. Sensor responses due to signal amplification varied depending on the concentration of synthetic miRNAs. It was confirmed that normalization (a ratio of working sensor response to reference sensor response) screened out background interferences by manipulating data and minimized non-uniformity in the photocatalytic silver staining step by suppressing disturbances to both working sensor signal and reference sensor signal. Finally, we were able to successfully detect target miRNAs in cancer cell-derived exosomal miRNAs with performance comparable to the detection of synthetic miRNAs.
chemistry, analytical,nanoscience & nanotechnology,instruments & instrumentation,physics, applied
What problem does this paper attempt to address?
The paper aims to address the following key issues: 1. **Developing highly sensitive and reproducible detection techniques**: Researchers have developed a technology based on a Surface Acoustic Wave (SAW) sensor array for the detection of microRNA (miRNA). This technology utilizes the signal enhancement effect of photocatalytic silver staining on Titanium Dioxide (TiO2) nanoparticles to achieve highly sensitive detection of miRNA and improves the reproducibility of detection results through built-in reference sensors. 2. **Simultaneous detection of exosomal miRNA derived from cancer cells**: The research focuses on the simultaneous detection of three cancer-related miRNAs (miR-21, miR-106b, and miR-155), which are upregulated in exosomes and considered important biomarkers for cancer. 3. **Overcoming background interference and non-specific adsorption issues**: To improve the reliability and accuracy of detection, the study introduces internal reference sensors to reduce the impact of background interference, such as non-specific protein adsorption. By normalizing the response of the working sensor with the response of the reference sensor, background interference can be effectively screened out and non-uniformity reduced. 4. **Achieving low detection limits**: The technology in the study significantly lowers the detection limit through signal amplification strategies, which is crucial for early cancer diagnosis. 5. **Simplifying the detection process**: Compared to traditional labeling methods, this technology does not require complex sample preprocessing steps, making the entire detection process simpler and more cost-effective. In summary, the main goal of this paper is to develop a novel SAW sensor array technology for the efficient, sensitive, and simultaneous detection of cancer-related miRNAs, providing a powerful tool for early cancer diagnosis.