Deep Learning for Motion Artifact-Suppressed OCTA Image Generation from Both Repeated and Adjacent OCT Scans

Zhefan Lin,Qinqin Zhang,Gongpu Lan,Jingjiang Xu,Jia Qin,Lin An,Yanping Huang
DOI: https://doi.org/10.3390/math12030446
IF: 2.4
2024-01-31
Mathematics
Abstract:Optical coherence tomography angiography (OCTA) is a popular technique for imaging microvascular networks, but OCTA image quality is commonly affected by motion artifacts. Deep learning (DL) has been used to generate OCTA images from structural OCT images, yet limitations persist, such as low label image quality caused by motion and insufficient use of neighborhood information. In this study, an attention-based U-Net incorporating both repeated and adjacent structural OCT images in network input and high-quality label OCTA images in training was proposed to generate high-quality OCTA images with motion artifact suppression. A sliding-window correlation-based adjacent position (SWCB-AP) image fusion method was proposed to generate high-quality OCTA label images with suppressed motion noise. Six different DL schemes with various configurations of network inputs and label images were compared to demonstrate the superiority of the proposed method. Motion artifact severity was evaluated by a motion noise index in B-scan (MNI-B) and in en-face (MNI-C) OCTA images, which were specifically defined in this study for the purpose of evaluating various DL models' capability in motion noise suppression. Experimental results on a nailfold OCTA image dataset showed that the proposed DL method generated the best results with a peak signal-to-noise ratio (PSNR) of 32.666 ± 7.010 dB, structural similarity (SSIM) of 0.926 ± 0.051, mean absolute error (MAE) of 1.798 ± 1.575, and MNI-B of 0.528 ± 0.124 in B-scan OCTA images and a contrast-to-noise ratio (CNR) of 1.420 ± 0.291 and MNI-C of 0.156 ± 0.057 in en-face OCTA images. Our proposed DL approach generated OCTA images with improved blood flow contrast and reduced motion artifacts, which could be used as a fundamental signal processing module in generating high-quality OCTA images from structural OCT images.
mathematics
What problem does this paper attempt to address?
### Problems the Paper Aims to Solve This paper aims to address the common issue of motion artifacts in Optical Coherence Tomography Angiography (OCTA). Specifically, the quality of OCTA images is often affected by motion artifacts, which interfere with the extraction of the true vascular network and the accurate quantification of vascular information. Although previous studies have used deep learning techniques to generate OCTA images, existing methods still have limitations in dealing with motion artifacts, such as low-quality label images leading to motion artifacts and insufficient utilization of neighborhood information. To address these issues, the authors propose an attention-based U-Net model that combines repeated and adjacent structural OCT images as input and uses high-quality labeled OCTA images for training to generate high-quality OCTA images with suppressed motion artifacts. Additionally, the authors propose a Sliding Window Correlation-Based Attention Pooling (SWCB-AP) method to generate high-quality labeled OCTA images, further reducing motion noise. ### Key Points Summary 1. **Problem Background**: - OCTA is a commonly used microvascular network imaging technique, but its image quality is often affected by motion artifacts. - Existing deep learning methods can generate OCTA images, but they still have shortcomings in dealing with motion artifacts. 2. **Solution**: - An attention-based U-Net model is proposed, combining repeated and adjacent structural OCT images as input. - High-quality labeled OCTA images are used for training to improve the quality of generated images and suppress motion artifacts. - A Sliding Window Correlation-Based Attention Pooling (SWCB-AP) method is introduced to generate high-quality labeled OCTA images. 3. **Evaluation Methods**: - Two specific evaluation metrics are defined: Motion Noise Index in B-scan OCTA images (MNI-B) and Motion Noise Index in en-face OCTA images (MNI-C). - The proposed method is experimentally validated on multiple evaluation metrics, including Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index (SSIM), Mean Absolute Error (MAE), and Contrast-to-Noise Ratio (CNR). 4. **Experimental Results**: - Experimental results show that the proposed method outperforms other methods on multiple evaluation metrics, particularly in suppressing motion artifacts. Through these methods, this paper provides an effective solution for generating high-quality OCTA images, which helps improve the accuracy of clinical disease assessment and biomedical research.