ASPYRE-Lung: validation of a simple, fast, robust and novel method for multi-variant genomic analysis of actionable NSCLC variants in FFPE tissue

Ryan T. Evans,Elizabeth Gillon-Zhang,Julia N. Brown,Katherine E. Knudsen,Candace King,Amanda S. Green,Ana-Luisa Silva,Justyna M. Mordaka,Rebecca N. Palmer,Alessandro Tomassini,Alejandra Collazos,Christina Xyrafaki,Iyelola Turner,Chau Ha Ho,Dilyara Nugent,Jinsy Jose,Simonetta Andreazza,Nicola D. Potts,Kristine von Bargen,Eleanor R. Gray,Magdalena Stolarek-Januszkiewicz,Aishling Cooke,Honey V. Reddi,Barnaby W. Balmforth,Robert J. Osborne
DOI: https://doi.org/10.3389/fonc.2024.1420162
IF: 4.7
2024-09-26
Frontiers in Oncology
Abstract:Introduction: Genomic variant testing of tumors is a critical gateway for patients to access the full potential of personalized oncology therapeutics. Current methods such as next-generation sequencing are costly and challenging to interpret, while PCR assays are limited in the number of variants they can cover. We developed ASPYRE ® (Allele-Specific PYrophosphorolysis REaction) technology to address the urgent need for rapid, accessible and affordable diagnostics informing actionable genomic target variants of a given cancer. The targeted ASPYRE-Lung panel for non-small cell carcinoma covers 114 variants in 11 genes ( ALK, BRAF, EGFR, ERBB2, KRAS, RET, ROS1, MET & NTRK1/2/3 ) to robustly inform clinical management. The assay detects single nucleotide variants, insertions, deletions, and gene fusions from tissue-derived DNA and RNA simultaneously. Methods: We tested the limit of detection, specificity, analytical accuracy and analytical precision of ASPYRE-Lung using FFPE lung tissue samples from patients with non-small cell lung carcinoma, variant-negative FFPE tissue from healthy donors, and FFPE-based contrived samples with controllable variant allele fractions. Results: The sensitivity of ASPYRE-Lung was determined to be ≤ 3% variant allele fraction for single nucleotide variants and insertions or deletions, 100 copies for fusions, and 200 copies for MET exon 14 skipping. The specificity was 100% with no false positive results. The analytical accuracy test yielded no discordant calls between ASPYRE-Lung and expected results for clinical samples (via orthogonal testing) or contrived samples, and results were replicable across operators, reagent lots, runs, and real-time PCR instruments with a high degree of precision. Conclusions: The technology is simple and fast, requiring only four reagent transfer steps using standard laboratory equipment (PCR and qPCR instruments) with analysis via a cloud-based algorithm. The ASPYRE-Lung assay has the potential to be transformative in facilitating access to rapid, actionable molecular profiling of tissue for patients with non-small cell carcinoma.
oncology
What problem does this paper attempt to address?