Automatic segmentation of 15 critical anatomical labels and measurements of cardiac axis and cardiothoracic ratio in fetal four chambers using nnU-NetV2

Bocheng Liang,Fengfeng Peng,Dandan Luo,Qing Zeng,Huaxuan Wen,Bowen Zheng,Zhiying Zou,Liting An,Huiying Wen,Xin Wen,Yimei Liao,Ying Yuan,Shengli Li
DOI: https://doi.org/10.1186/s12911-024-02527-x
IF: 3.298
2024-05-24
BMC Medical Informatics and Decision Making
Abstract:Accurate segmentation of critical anatomical structures in fetal four-chamber view images is essential for the early detection of congenital heart defects. Current prenatal screening methods rely on manual measurements, which are time-consuming and prone to inter-observer variability. This study develops an AI-based model using the state-of-the-art nnU-NetV2 architecture for automatic segmentation and measurement of key anatomical structures in fetal four-chamber view images.
medical informatics
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to improve the accurate segmentation and measurement of key anatomical structures in fetal four - chamber heart images, in order to realize the automation of early detection of congenital heart disease. Specifically: 1. **Reduce the time consumption of manual measurement and inter - observer differences**: Current prenatal screening methods rely on manual measurement. This method is not only time - consuming but also easily affected by the skill levels of different observers, resulting in inconsistent measurement results. 2. **Improve the efficiency and reliability of prenatal heart screening**: By developing an artificial intelligence - based model, using the state - of - the - art nnU - NetV2 architecture, to automatically segment and measure key anatomical structures in fetal four - chamber heart images, aiming to improve the efficiency and accuracy of prenatal heart screening. 3. **Assist inexperienced ultrasound doctors**: This model also aims to help junior ultrasound doctors and medical workers in areas with limited resources perform routine screening tasks, reduce their daily workload, and guide them on how to perform correct measurements. By constructing and training an AI model based on nnU - NetV2, the paper achieved the automatic segmentation of 15 key anatomical structures in fetal four - chamber heart images and automatically calculated the cardiac axis (CAx) and cardiothoracic ratio (CTR), thus achieving the above - mentioned goals. The research results show that this model performs excellently in terms of segmentation accuracy and calculation of clinically relevant parameters, and has a high degree of consistency with the manual measurement results of senior ultrasound doctors. This provides strong support for improving the efficiency and reliability of prenatal heart screening.