Comparative Analysis of AB vs. ABO-specific Plasma for Desensitization in Blood Group O Recipients: An In Vitro Study

Young Ae Lim
DOI: https://doi.org/10.3343/alm.2023.0393
IF: 4.941
2024-01-19
Annals of Laboratory Medicine
Abstract:Neutralizing capacity measurement (NCM) of soluble ABH substances (SAS) in plasma was assessed to guide the selection of the appropriate ABO group of fresh-frozen plasma (FFP) for plasma exchange (PE) in blood group O recipients with ABO-incompatible transplantations. Neutralizing capacity was assessed by measuring anti-A and/or anti-B titers in samples comprising one unit of O FFP and 10 O EDTA plasma samples and subtracting the binary logarithm of the titer in each group with a saline dilution. Ten EDTA plasma samples with Lewis b (Le<sup>b</sup>) antigen positivity and 10 sets of pooled FFP from each blood group were used as diluents. In O FFP, the NCM values (mean±SD) were 3.4±0.52 (2.6±0.52) and 2.6±0.52 (1.5±0.3) in B and AB for IgM (total antibody) anti-B (both <i>P</i>&lt;0.001), and in the 10 O EDTA plasma samples, they were 3.9±0.88 (3.1±0.88) and 3.2±0.79 (2.4±0.97) for IgM (<i>P</i>=0.0013) and total anti-B (<i>P</i>=0.025), respectively. <i>In vitro</i> analysis revealed that B FFP is more effective than AB FFP in reducing IgM and total anti-B antibody titers in O recipients, regardless of Le<sup>b</sup> antigen positivity.
medical laboratory technology
What problem does this paper attempt to address?